Canadian Certificate Of Conformity No: FM17CA0156X
The ambient operating temperature range of the PR 6130/68S-Temp and PR 6021/68S-Temp
Cable Junction Box is up to -40°C to +60°C.
Electrical Data:
For intrinsic safety, the Cable Junction Boxes are assigned the following input parameters:
Ui ≤ 25V, Ii ≤ 370mA, Pi = any, Ci = 0, Li =0
For all other protection techniques, the electroinic connection has the following values:
Ui ≤ 25V, Ii ≤ 370mA, Pi = any
PR 6130/6[a][b] and PR 6021/68S Cable Juction Box
[a] = Size; 4, 5 or 8
[b] = S, Sa or C
PR 6130/64Sa-Temp, PR 6130/64C-Temp and PR 6130/65S-Temp Cable Junction Box
None
PR 6130/68S-Temp and PR 6021/68S-Temp Cable Junction Box
None
13.
Specific Conditions of Use:
1. Under certain extreme circumstances, the non-metallic label may generate an ignition-capable level of
electrostatic charge. Therefore particularly when it is used for applications that specifically require Zone 20,
21 or 22 Group III, or Class I and II, Division 1 or 2 located equipment, the equipment shall not be installed in
a location where the external conditions are conducive to the build-up
14.
Test and Assessment Procedure and Conditions:
This Certificate has been issued in accordance with FM Approvals Canadian Certification Scheme.
15.
Schedule Drawings
A copy of the technical documentation has been kept by FM Approvals.
16.
Certificate History
Details of the supplements to this certificate are described below:
Date
th
8
August 2014
th
6
October 2017
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA
T: +1 (1) 781 762 4300 F: +1 (1) 781 762 9375 E-mail:
F 348 (Mar 16)
SCHEDULE
Description
Original Issue.
Supplement 3:
Report Reference: – RR210028 dated 6
Description of the Change: Company name change from Sartorius Mechatronics T&H
GmbH. Certificate reformated.
information@fmapprovals.com www.fmapprovals.com
th
October 2017
Page 3 of 4