INTRODUCTION
EN
This instruction sheet provides you with the information required to safely own and
operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship
and material, and has been engineered to give you long and reliable service.
Little Giant pumps are carefully tested, inspected, and packaged to ensure safe
delivery and operation. Please examine your pump carefully to ensure that no
damage occurred during shipment. If damage has occurred, please contact the
place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW THE
PUMP'S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
1. Make certain that the unit is disconnected from the power source before
attempting to service or remove any component.
2. Do not use to pump flammable or explosive fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in explosive atmospheres. Pump should only be used
with liquids compatible with pump component materials.
3. Do not handle pump with wet hands or when standing on a wet or damp
surface or in water.
4. This pump is supplied with a grounding conductor and/or grounding type
attachment plug. To reduce the risk of electric shock. be certain that it is
connected to a properly grounded grounding type receptacle.
5. In any installation where property damage and/or personal injury might result
from an inoperative or leaking pump due to power outages, discharge line
blockage, or any other reason, a backup system(s) and/or alarm should be
used.
6. Support pump and piping when assembling and when installed. Failure to do
so may cause piping to break, pump to fall, motor bearing failures, etc.
7. If pump is an oil-filled pump, the motor housing is filled with a dielectric
lubricant at the factory for optimum motor heat transfer and lifetime
lubrication of the bearings. Use of any other lubricant could cause damage
and void the warranty. This lubricant is non-toxic; however, if it escapes the
motor housing, it should be removed from the surface quickly by placing
newspapers or other absorbent material on the water surface to soak it up,
so aquatic life is undisturbed.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not connect to voltage
other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third prong is to ground
the pump to prevent possible electrical shock hazard. DO NOT REMOVE the
third prong from the plug. A separate branch circuit is recommended. Do not
use an extension cord.
3. If the cord is equipped with stripped lead wires, such as on 230v models,
be sure that the lead wires are connected to a power source correctly. The
(green/yellow) wire is the ground. The (blue or white) and the (brown or
black) are live.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY
AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.
1. The PE-2H-PW model pumps must be operated with the volute intake below
the liquid level.
2. The pumps can be placed in any position.
3. The volute on these pumps can be rotated 90° to allow for different pump
orientations. To rotate the volute, remove the three volute screws (item 2).
Remove and rotate the volute and gasket and reinstall the three screws in the
PE-2H-PW SERIES
MODÈLES DE LA
SÉRIE PE-2H-PW
MODELOS DE LA
SERIE PE-2H-PW
WARNING
WARNING
OPERATION
WARNING
additional holes in the front of the pump housing. NOTE: USING EXCESSIVE
TORQUE ON THE VOLUTE SCREWS COULD CAUSE THE HOLES TO STRIP.
4. The weight of the pumps must be supported adequately. DO NOT support the
pumps by the discharge connection alone. Pumps may be supported by using
the two mounting holes in the back of the pump. The holes are designed for
#8 self-tapping screws. Hole depth is .37. DO NOT exceed the hole depth.
5. Do not attempt to restrict the intake side of these pumps. Restricting the intake
may cause damage to the seal and may starve the pump. If you require reduced
flow rates place the included FC-1/4" valve on the discharge side of the pump or if
flexible vinyl tubing is used, a clamp can be used on the tubing to restrict the flow.
6. Do not let the unit operate dry. It is designed to be cooled by pumping fluid. You
may damage the seal and the motor may fail if the pump is allowed to run dry.
7. If the unit is going to be idle for a period of time, follow the cleaning instructions
outlined in the next section. Do not let the unit freeze in the wintertime. This may
cause cracking or distortion that may destroy the unit.
8. If fused type plug is used on 230 volt units, a 1.0 amp fuse is
recommended.
SERVICE INSTRUCTIONS
MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER
SOURCE
BEFORE
ATTEMPTING
COMPONENT!
1. This unit is permanently lubricated. Oiling is not required. The power cord on
these units cannot be replaced. In case of damage the whole unit must be
replaced.
2. First remove the intake screen from the pump. Screen is snapped on and can
be removed by pulling. Then remove the three screws which attach the volute.
3. Lightly clean any corrosion or debris which may clog the impeller. Use a
brush and penetrating oil and lightly scrape to remove encrusted material.
4. Turn the impeller by hand to make sure it turns freely. Set pump down so the
pump and impeller are not touching anything. Plug the unit into GFCI circuit
for 10 seconds to see if the impeller turns: a) If it is rotating and GFCI did not
trip, unplug unit and install parts in reverse order in which they were removed.
b) If it does not rotate, if pump is tripping circuit breakers, or not operating
properly after cleaning, return to Little Giant or its authorized service center.
DO NOT attempt repairs yourself.
5. Be certain power cord is in good condition and contains no nicks or cuts.
INTRODUCTION
FR
Cette feuille d'instructions vous fournit les informations nécessaires pour entretenir
et faire fonctionner votre produit Little Giant. Conserver ces directives afin de
pouvoir les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec
des matériaux de la plus haute qualité et a été conçu pour durer longtemps et offrir
un service fiable. Les produits Little Giant sont soigneusement testés, inspectés
et emballés afin d'en assurer la sécurité de fonctionnement et une livraison en
bonne condition. Vérifier attentivement le produit afin de vous assurer qu'il n'a
pas été endommagé pendant le transport. S'il est endommagé, veuillez contacter
l'entreprise qui vous l'a vendu. Si une réparation ou un remplacement est requis,
elle vous prêtera assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À
L'INSTALLATION, À L'UTILISATION OU À L'ENTRETIEN DU PRODUIT LITTLE
GIANT. SE FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES ET LES
RISQUES POTENTIELS DU PRODUIT. ASSURER SA PROPRE PROTECTION
ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES DE SÉCURITÉ.
LE NON-RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER DES BLESSURES
WARNING
ET/OU DES DOMMAGES MATÉRIELS!
AVERTISSEMENT
DIRECTIVES DE SECURITE
1. Veiller à débrancher l'appareil de sa source d'alimentation électrique avant
l'entretien ou la dépose d'une ou de plusieurs piéces.
2. Ne pas pomper des fluides explosifs ou inflammables tels qu'essence, mazout,
kérosène, etc. Ne pas employer dans une atmosphère comportant des risques de
déflagration. La pompe ne doit servir qu'à pomper des liquides compatibles avec
les matériaux utilisés pour la fabrication des éléments qui la composent.
3. Ne pas manipuler la pompe les mains humides, les pieds posés sur une
surface mouillée ou humide, ou les pieds dans l'eau.
4. Cette pompe est équipée d'un conducteur de mise à la terre et ou d'une fiche
de branchement à prise de terre. Pour réduire les risques d'électrocution,
s'assurer qu'elle est bien raccordée à une prise de courant appropriée
comportant une borne de mise à la terre.
5. Dans le cas de toute installation où des dommages matériels ou des
blessures pourraient survenir par suite de l'emploi d'une pompe qui ne
fonctionnerait pas ou qui fuirait à cause d'une panne de courant, d'une
1
WARNING
TO
SERVICE
OR
REMOVE
AVERTISSEMENT
ANY

Publicité

loading

Sommaire des Matières pour Franklin Electric Little Giant PE-2H-PW Serie

  • Page 1 4. The weight of the pumps must be supported adequately. DO NOT support the pumps by the discharge connection alone. Pumps may be supported by using SÉRIE PE-2H-PW Franklin Electric Co., Inc. the two mounting holes in the back of the pump. The holes are designed for Oklahoma City, OK 73127 #8 self-tapping screws.
  • Page 2 canalisation de refoulement bouchée ou de toute autre raison, prévoir disjoncteur de fuite à la terre pour déterminer si la roue à aubes toune librement; a) Si elle tourne bien et si le disjoncteur ne se déclenche pas, l’emploi de(s) dispositif(s) de secours ou d’alarme voulu(s). débrancher alors l’appareil et poser les pièces dans l’ordre inverse de la 6.
  • Page 3 DEFECTIVE PRODUCT. II. Instructions Applicable to this Limited Warranty Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this warranty are free from defects 1. Consumers wishing to submit a warranty claim must return the products accompanied in materials or workmanship of the Company that exist at the time of sale by the by this warranty to the point of purchase for warranty consideration.
  • Page 4 6. Products damaged by normal wear and tear, normal maintenance services and the parts used in connection with such service, or any other conditions beyond the control Franklin Electric Company, Inc et ses filiales (ci-après « la Société ») garantit que of the Company.
  • Page 5 11. Les produits dans lesquels la pompe a été utilisée pour pomper ou faire circuler des Franklin Electric Company, Inc y sus subsidiarias (en adelante “la Compañía”) liquides autres que de l’eau douce à température ambiante.
  • Page 6 4. Cualquier producto que sea operado con cualquier accesorio, equipo, componente, LA COMPAÑÍA NO SERÁ RESPONSABLE POR LOS DAÑOS ACCIDENTALES, o pieza que no esté específicamente aprobada por la Compañía. CONSECUENTES O ESPECIALES TALES COMO, PERO NO LIMITADOS A: 5. El uso de piezas de repuesto que no sean vendidas por la Compañía, la adición no autorizada de productos que no sean de la Compañía a productos de la Compañía, DAÑOS A O PÉRDIDA DE OTRA PROPIEDAD O EQUIPO, PÉRDIDAS DE y la alteración no autorizada de productos de la Compañía.
  • Page 8 Pour l’aide technique, entrez s’il vous plaît en contact ..1.888.956.0000 Para la ayuda técnica, por favor póngase en contacto ..1.888.956.0000 www.lg-outdoor.com customerservice@lgpc.com Form 998114 - 11/2014 Rev 002 ©2014 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.