Franklin Electric Co., Inc.
Oklahoma City, OK 73157-2010
www.lg-outdoor.com
Customerservice@lgpc.com
INTRODUCTION
EN
This instruction sheet provides you with the information required to safely own and
operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship and
material, and has been engineered to give you long and reliable service. Little Giant
pumps are carefully tested, inspected, and packaged to ensure safe delivery and
operation. Please examine your pump carefully to ensure that no damage occurred
during shipment. If damage has occurred, please contact the place of purchase. They
will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW THE
PUMP'S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
DESCRIPTION
This is a magnetic-drive, submersible, statuary fountain pump. It has an epoxy-
encapsulated motor and a thermoplastic housing. A permanent magnet is attached
to the impeller and acts as the rotor would in a conventional motor.
SAFETY GUIDELINES
MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER
SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in explosive atmospheres. Pump should only be used with
clean water. Do not use to pump heated liquids. Pump should only be used with
liquids compatible with pump component material.
Do not handle pump with wet hands or when standing on a wet or damp surface
or in water.
This pump is supplied with a grounding conductor and/or grounding type attachment
plug. To reduce the risk of electric shock, be certain that it is connected to a properly
grounded grounding type receptacle.
Support pump and piping when assembling and when installed. Failure to do so may
cause piping to break, pump or motor to fall, etc.
ELECTRICAL CONNECTIONS
1.
Check the pump label for proper voltage required. Do not connect to voltage
other than that shown.
2.
This pump is supplied with a 3-prong electrical plug. The third prong grounds
the pump to prevent possible electrical shock hazard. DO NOT REMOVE the third
prong from the plug. A separate branch circuit is recommended. Do not use an
extension cord.
3.
The National Electric Code requires that a ground fault circuit interrupter (GFCI) be
used in the branch circuit supplying fountain pumps and other pond equipment.
4.
To reduce the risk of electric shock, use only on portable, self-contained
fountains no larger than five feet in any dimension.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY AND
DISASSEMBLY OF YOUR PUMP.
1.
Operate the pump in clean, fresh water completely submerged. Do not let the
pump run dry.
2.
The pump can be placed in any position. There are suction cup feet provided
with the pump. To install the suction cups, wet the ends and slide them into the
slots on the bottom of the pump housing.
3.
Support the weight of the pump adequately. DO NOT support the pump by the
discharge connection.
4.
Adjust the flow rate by turning the flow control located on the front of the pump.
To reduce the flow rate further, place a valve on the discharge side of the pump
or, if flexible tubing is used, a clamp on the tubing.
5.
If the pump will be idle for an extended period, clean it according to the SERVICE
INSTRUCTIONS section.
SERVICE INSTRUCTIONS
WARNING: Disconnect the pump from the power source before attempting to
service or remove any component.
WARNI
NG: Do not modify, cut, saw, sand, or grind any part of the pump. Doing so
can cause harmful emissions.
PES SERIES PUMP
PES SÉRIE POMPE
PES SERIE BOMBA
WARNING
WARNING
OPERATION
WARNING
CAUTION: Consult instruction sheet illustrations for proper assembly and
disassembly of your pump.
NOTE: This pump is permanently lubricated. Oiling is not required.
1. Remove the front plate/screen (1) by gently squeezing its sides and pulling it
from the main body.
2. Turn the volute plate (2) 1/8-turn counter-clockwise (gently using pliers, if
necessary) and remove it from the pump body.
3. The shaft/impeller assembly (3), and rubber mounting end cups (4) may also come
out with the volute plate. If not, remove the shaft/impeller assembly, then check for two
rubber end cups, which should be located on each end of the shaft. One of the cups
may remain inside the pump body impeller cavity and the other may remain inside the
volute plate. If so, make sure they are still there when reassembling the pump.
4. Use a small brush or stream of water to clean any corrosion or debris from the
impeller, shaft, and the impeller cavity.
5. Reassemble the parts in reverse order.
6. Inspect the power cord to ensure that it is in good condition and has no nicks or cuts.
7. If, after servicing, the pump trips its circuit breaker or GFCI, or otherwise does
not operate properly, replace pump.
1
2
3
INTRODUCTION
FR
Cette feuille d'instructions vous fournit les informations nécessaires pour entretenir
et faire fonctionner votre produit Little Giant. Conserver ces directives afin de pou-
voir les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec des
matériaux de la plus haute qualité et a été conçu pour durer longtemps et offrir un service
fiable. Les produits Little Giant sont soigneusement testés, inspectés et emballés afin
PES-130-PW
d'en assurer la sécurité de fonctionnement et une livraison en bonne condition. Vérifier
attentivement le produit afin de vous assurer qu'il n'a pas été endommagé pendant le
transport. S'il est endommagé, veuillez contacter l'entreprise qui vous l'a vendu. Si une
réparation ou un remplacement est requis, elle vous prêtera assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À L'INSTALLATION,
À L'UTILISATION OU À L'ENTRETIEN DU PRODUIT LITTLE GIANT. SE FAMILIARISER
AVEC LES APPLICATIONS, LES LIMITES ET LES RISQUES POTENTIELS DU
PRODUIT. ASSURER SA PROPRE PROTECTION ET CELLE DES AUTRES EN SUIVANT
TOUTES LES RÈGLES DE SÉCURITÉ. LE NON-RESPECT DE CES DIRECTIVES PEUT
ENTRAÎNER DES BLESSURES ET/OU DES DOMMAGES MATÉRIELS!
DESCRIPTION
Cette pompe est une pompe submersible enrobée d'époxy. Son boîtier extérieur est
WARNING
en thermoplastique durable. Le boîtier est rempli d'une résine époxyde à transfert
de chaleur spéciale.
AVERTISSEMENT
DIRECTIVES DE SECURITE
VEILLER À DÉBRANCHER L'APPAREIL DE SA SOURCE D'ALIMENTATION ÉLECTRIQUE
AVANT L'ENTRETIEN OU LA DÉPOSE D'UNE OU DE PLUSIEURS PIÉCES.
Ne pas pomper des fluides explosifs ou inflammables tels qu'essence, mazout,
kérosène, etc. Ne pas employer dans une atmosphère comportant des risques de
déflagration. La pompe ne doit servir qu'à pomper des liquides compatibles avec les
matériaux utilisés pour la fabrication des éléments qui la composent.
Ne pas manipuler la pompe les mains humides, les pieds posés sur une surface
mouillée ou humide, ou les pieds dans l'eau.
Cette pompe est équipée d'un conducteur de mise à la terre et ou d'une fiche de
branchement à prise de terre. Pour réduire les risques d'électrocution, s'assurer qu'elle est
bien raccordée à une prise de courant appropriée comportant une borne de mise à la terre.
Veiller à bien étayer la pompe et la tuyauterie
WARNING
place. Sinon, non seulement les tuyaux risqueraient de se déchirer mais la pompe
pourrait également faire défaut et lemoteur pourraient subir des dommages, etc.
AVERTISSEMENT
CONNEXIONS ELECTRIQUES
1. Consulter l'étiquette de la pompe pour connaître la tension appropriée. Ne pas
raccorder à une source autre que la tension spécifiée.
4
Fig. 1
AVERTISSEMENT
lors du montage et de la mise en
AVERTISSEMENT
1