Using the inverter
10.2
Status indications
The blue LED (fig. 2 2) shows the operating condition of the inverter.
Display
Constantly lit
Long flash, short interruption
Quick flash
Off
The inverter switches off if:
• The battery voltage drops below 10 V (12 Vg connection) or
20 V (24 Vg connection).
• The battery voltage exceeds 16.5 V (12 Vg connection) or
33 V (24 Vg connection).
• The inverter is overloaded.
• The inverter overheats.
➤ If this happens, shut down the inverter with the main switch (fig. 2 1).
➤ Check that the inverter is sufficiently ventilated and that the ventilation grilles are
unimpeded.
➤ Wait 5 – 10 minutes and switch the inverter on again without any electric
consumers.
10.3
Switching to energy-saving mode
I
NOTE
The energy-saving mode can be set with a remote control only.
18
Input voltage
Normal mode
Inverter overheated/Overload
Overvoltage/Undervoltage
Other fault
SinePower
EN