INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum height
of 5 feet (1.5 m) where small children cannot reach, away from
moving parts of door and door hardware. If installing into drywall,
drill 5/32" holes and use the anchors provided. For pre-wired
installations (as in new home construction), it may be mounted to
a single gang box (Figure 1).
1. Strip 7/16" (11 mm) of insulation from one end of bell wire and
connect to the two screw terminals on back of door control by
color: white wire to 2 and white/red wire to the 1 (Figure 2).
2. Door Control Button: Fasten securely with 6ABx1-1/2" screws.
Console Model: Remove cover by gently prying along one
side with a screwdriver (Figure 3). Fasten with 6ABx1-1/4"
self-tapping screws (drywall installation) or 6-32x1"
machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to protrude above
wall surface.
• Position bottom of door control on screw head and slide down
to secure. Adjust screw for snug fi t.
• Drill and install top screw with care to avoid cracking plastic
housing. DO NOT overtighten.
• Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to secure
wire in several places. DO NOT pierce wire with a staple,
creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire. Connect
bell wire to the quick-connect terminals as follows: white to
white and white/red to red (Figure 4).
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment warning
label to wall near door control, and manual release/safety
reverse test label in a prominent location on inside of garage
door.
NOTE: DO NOT connect power and operate opener at this time.
The trolley will travel to the full open position but will not return to
the close position until the sensor beam is connected and properly
aligned.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
Figure 1
PRE-WIRED
INSTALLATION
Figure 3
To Replace,
To Remove,
Insert
Twist
Top Tabs
Here
First
17
Screw 6ABx1-1/2"
Door Control Button
Screw 6ABx1-1/4"
Control Console (std installation)
Screw 6-32x1"
Control Console (pre-wired)
Figure 2
24 Volt
2-Conductor
Bell Wire
Figure 4
2-Conductor
Lighted Push
Button
Bell Wire
DOOR
CONTROL
STANDARD
BUTTON
CONTROL CONSOLE
To release or insert wire, push in
tab with screwdriver tip
Strip wire 7/16" (11 mm)
Red White Grey
HARDWARE SHOWN
ACTUAL SIZE
Insulated
Staples
Drywall Anchors
Bell
Wire
Terminal Screws
Top
Mounting
Hole
Terminal
Screws
Bottom
Bell
Mounting
Wire
Hole
(BACK VIEW)
Quick-Connect
Terminals
Door Control
Connections