Installation
Please follow the steps below for installation.
1. Connect a DisplayPort source device to the input port of the DisplayPort transmitter unit using a DP
cable.
2. Insert the supplied QSFP modules into the Optical Out and Optical In ports respectively.
3. Connect one end of the Duplex LC OS1 single mode fibre cable (9/125μm) to the QSFP module
fixed into the Optical Out port of the transmitter unit, and the other end of the cable to the QSFP
module positioned in the Optical In port of the receiver. Please use the correct fibre optic cabling.
4. Connect a DisplayPort display device to the DisplayPort output port on the receiver unit using a DP
cable.
5. Power on both the DisplayPort source and display.
6. Plug the DC power supplies into the transmitter and receiver units, the Power LED will illuminate on
both units. If no issues are present on either unit, all LEDs will be illuminated blue on both units.
7. Once a link has been established, between the source and transmitter, and the display and the
receiver, the corresponding link LED will illuminate.
8. Once a link has been established, between the transmitter and receiver, the corresponding link LED
will illuminate.