I.
From inside the fi rebox, install the 5" (127mm) exhaust collar with gasket and
the exhaust outlet reducer plate up through the top of the fi rebox, and secure
with the the 4 hex head 3/4" black screws supplied in the manual baggie
(Fig. 3).
note:
Do not overtighten. The gasket needs only to be snug against the fi rebox.
J.
Fully secure exhaust outlet reducer using 4 self-tapping screws (supplied)
(Fig. 3).
K.
Reinstall the top defl ector, log set, glass door, and safety barrier.
I
I
J
J
J
I
EXHAUST
FLUE COLLAR
venting requirements
J
I
Fig. 4
W415-1794 / I / 03.23.22
EN
Fig. 3
21