venting requirements
EN
2.8
top exit
WARNING
!
Failure to create a seal to the fi rebox with the exhaust collar assembly will cause the appliance to function
improperly and can cause injury or property damage.
note:
This appliance has been factory shipped as a rear vent.
A.
Remove the safety barrier and glass door (see "safety barrier & door removal / installation" section).
B.
Remove the contents from the fi rebox and set aside.
You will need the exhaust and air inlet collar.
C.
To ease assembly, remove the 4 hex head screws,
securing the defl ector from inside the top front of the
fi rebox (Fig. 1). Set defl ector aside.
D.
Remove the outer cover plate and gasket by removing the 4 screws. Install the outer cover plate and
gasket onto the back of the appliance using the 4 previously removed screws (Fig. 2).
E.
Remove the 1 1/2" (38.1mm) thick batt of insulation and discard (Fig. 2).
F.
Remove the 4 screws securing the inner cover plate, 'o' ring, and gasket. Remove the inner cover plate
and discard (Fig. 2).
G.
Reinstall the 'o' ring and gasket into the appliance using the previously removed screws (Fig. 2).
H.
Place the 8" (203mm) intake collar and gasket onto the top of the appliance and secure using 4 screws.
tip:
The manual baggie supplies the gasket and screws (packaged in another separate baggie).
1 1/2" INSULATION BATT
20
W415-1794 / I / 03.23.22
note:
Top baffl e must not be installed for top exit applications.