14. TECHNICAL DATA
Measuring category ..................................... CAT III 500V against ground potential
Max. measuring voltage .............................. 500 V
Analog display ............................................. With mirror scale
Input resistance V range .............................. approx. 10MΩ
Power supply ............................................... 9 V block battery + 2x AA
Operating temperature ................................ 0°C to +40°C
Storage temperature .................................... -10°C to +50°C
Operational height ....................................... max. 2000 m
Rel. humidity ................................................ <75%, non-condensing
Temperature for guaranteed accuracy ......... +20°C to +26°C
Weight ......................................................... approx. 460 g
Measurements (LxWxH) .............................. 160 x 105 x 40 (mm)
47