W 550
Problem
Atomisation too
coarse
Spray jet
pulsates
Coating
material causes
"paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose
18. Technical Data
Max. viscosity
Power source
Power consumption
Atomizing output:
Double insulation
Sound pressure level*
Sound pressure output*
Oscillation level**
Weight
* Measured in accordance with EN 50144-2-7:2000
** Measured in accordance with EN 60745-1
Cause
Viscosity of coating material too
high
Material volume too large
Material volume adjusting screw
turned too far to the right (+)
Nozzle contaminated
Air filter heavily soiled
Too little pressure build-up in
container
Coating material in container
running out
Air filter heavily soiled
Nozzle seal is missing or worn
Too much coating material
applied.
Distance to the object too large
Too much coating material
applied
Diaphragm soiled
Diaphragm defective
Technical Data
90 DIN-s
230 V
, 50 Hz
~
280 W
65 W
79 dB (A); Uncertainty K = 4 dB
92 dB (A); Uncertainty K = 4 dB
< 2.5 m/s²; Uncertainty K = 1.5 m/s
1,3 kg
Remedy
Thin
Turn material volume
adjusting screw to the
left (-)
Clean
Change
Tighten container
Refill
Change
Insert an intact nozzle seal
Turn material volume
adjusting screw to the
left (-)
Reduce distance
Turn material volume
adjusting screw to the
left (-)
Clean the diaphragm
Replace the diaphragm