Gartenpumpe_420610_420611.book Seite 23 Donnerstag, 17. September 2015 11:22 11
– Unscrew filter housing (6) and take out filter car-
tridge.
– If needed, soak filter cartridge in warm water for
a short while.
– Rinse filter cartridge with clear water; brush out
stubborn dirt from inside using a soft brush.
NOTICE! Danger of damage to the
device! Before installing the cleaned filter
cartridge, check to be sure that there are no
foreign particles inside!
Intake of particles will damage the pump!
– Insert cleaned filter cartridge into the filter hous-
ing.
– Screw filter housing back down. Ensure proper
location of the seal!
Storage
If there is danger of frost, dismantle the device and
accessories, clean and store them in a place pro-
tected from frost.
NOTICE! Danger of damage to the
device! Frost will damage the device and
accessories, since they always contain
water!
Error/Fault
Pump does not work.
Delivery rate too low.
Not enough pressure.
Dismantle and store
1. Turn off the device, unplug the mains plug.
2. Open pressure line (turn on water spigot or noz-
zle), allow water to completely run off.
3. Completely empty the pump by unscrewing the
water drain plug (6) on the underside of the
pump.
4. Dismantle the suction and pressure lines from
the device.
5. Store device in a frost-free room (at least 5 °C).
Faults and remedial measures
When something isn't working...
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the
vendor. You will save yourself a lot of trouble and
possibly money too.
Cause
No power supply?
Motor overheats due to high liquid
temperature?
Residual current protection switch
(FI-switch) activated?
Motor defective?
Water shortage?
Suction pipe not sealed?
Suction height too high?
Filter blocked or soiled?
Check valve blocked?
Water leak between motor and
pump, shaft sealing is not sealed?
Pump is blocked or defective?
Air in the pump or suction pipe?
Changed suction conditions in
spring (springs e. g. covered in
sand)?
DANGER! Risk of injury! Improperly per-
formed repairs can lead to the device not
functioning safely. This endangers yourself
and your environment.
Remedy
Check the cable, plug, and the fuse.
Eliminate cause of overheating.
(max. liquid temperature ► Techni-
cal data – p. 24)
Switch on FI-switch. If it happens
again contact the electric service
partner.
Contact your local vendor.
Ensure sufficient water supply.
Seal suction pipe, tighten screwed
connections.
Observe maximal suction height
(► Technical data – p. 24).
Suction height must be deducted
from the conveyance height.
Clean or replace filter.
Clean or replace valve.
Contact your local vendor.
Clean the pump with clean water
and remove the cause of the con-
tamination.
Fill pump case with water.
For suction pipes with check valve,
fill suction pipe with water.
Check spring and water quality.