Télécharger Imprimer la page

Kärcher SP 16.000 Dirt Manuel D'utilisation page 12

Publicité

Fault
The pump does not start
up, or stops suddenly
during operation
The pumping capacity
decreases
The delivery rate is too
low
Quick-Connect cannot
be opened or closed
Technical data
Device performance data
Mains voltage
Power frequency
Nominal power
Maximum flow rate
Pressure (max.)
Delivery height (max.)
Immersion depth (max.)
Perm. temp. feed fluid
Particle size (max.) of per-
missible feed fluids
Solids content in water
Minimum fluid level (manu-
al mode)
Residual fluid height
Weight (without accesso-
ries)
Subject to technical modifications.
Optimising the flow rate
The flow rate is further increased:
● The lifting height is reduced.
● The diameter of the hose used is increased.
● The length of the hose used is decreased.
● The smaller the pressure loss caused by the con-
nected up accessories.
12
Cause
The power supply is disconnected.
The thermal protection switch has
switched off the pump because of over-
heating.
Dirt particles block the suction area.
The suction area is clogged.
The maximum delivery head is exceed-
ed.
The hose diameter and the hose length
have been selected incorrectly.
The push-fit system is dirty.
SP
SP
16.000
22.000
Dirt
Dirt
V
230-240 230-240
Hz
50
50
W
550
750
l/h
16.000
22.000
MPa
0,08
0,08
(bar)
(0,8)
(0,8)
m
8
8
m
7
7
°C
5...35
5...35
mm
20
30
3
kg/m
>2,5
>2,5
mm
60
50
mm
25
35
kg
4,9
6,5
Rectification
1. Check the fuses and the electrical connec-
tions.
1. Pull the mains plug out of the socket.
2. Allow the pump to cool down.
3. Remove any dirt particles in the suction ar-
ea.
4. Clean the suction area.
5. Prevent the pump from running dry.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
1. Observe the maximum delivery head, see
chapter Technical data.
2. If necessary, select a greater hose diame-
ter or a shorter hose length, see chapter
Optimising the flow rate.
1. Remove the clip.
2. Clean the clip.
3. Install the clip.
Declaration of Conformity
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in circu-
lation by us. This declaration is invalidated by any chang-
es made to the machine that are not approved by us.
Product: Pump
Type: 1.645-xxx
Currently applicable EU Directives
2014/35/EU
2014/30/EU
2011/65/EU
2009/125/EC
Commission Regulation(s)
(EU) 2019/1781
Harmonised standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN IEC 63000: 2018