PROBLEM
CAUSE
The fire table
Hose from gas fire
emits a lot of
table is pinched
black smoke
when in use
Flame is being
obstructed at
burner ports or
mixing chamber of
the burn tube is
blocked or
obstructed
Sudden drop
Out of Gas
in gas flow, or
a reduced
Excess flow safety
flame height
device may have
been activated
Irregular
Burner ports are
flame pattern,
clogged or blocked
flame does
not run the full
length of the
burner
Flame blow
High or gusting
out
winds
Low on LP gas
Excess flow valve
tripped
24
SOLUTION
Make sure the hose is not pinched
between the fire table and the source of
the gas.
Make sure that the gas ports on the
burner are free of any lava rocks/fire
glass so that the flame can flow
naturally. Clear out the mixing chamber
located before the Venturi.
Check for gas in the LP gas tank.
Turn control knob to OFF, wait 30
seconds and light outdoor fire table.if
flames are still too low, reset the
excessive flow safety device by turning
off the control knob and LP gas tank
valve.
Disconnect regulator. Turn burner
control knob to HIGH. Wait at least 5
minutes. Turn burner control knob off.
Reconnect regulator and perform a
leak check at tank connection. Turn LP
gas tank valve on slowly, wait 30
seconds and then light outdoor fire
table.
Clean burner ports.Do this by inserting
a paperclip into each of the burner
ports to ensure they are not clogged.
WARNING: Make sure burner is not on,
and has had sufficient time to cool
before touching it.
Increase flame to HIGH setting.
Replace or refill LP gas tank.
Refer to Problem: Sudden drop in gas
flow.
PROBLEM
CAUSE
Flame seems
Ice has built up on
to lose heat
the outside of the
when burning
LP gas tank
in cold
because the
weather -
vaporization
temperature
process is too low
below 50°F
SOLUTION
Turn the control knob and the LP gas
tank to OFF.
Replace with a spare LP gas tank and
resume burning. Store the spare LP
gas tank in a well ventilated area, away
from children.
25