2. CONTROL BOX INSTALLATION
2.1.
Space requirements
2.2.
Connection to the terminals
The cables will be connected to the terminals according to the instructions hereunder
Rep
Designation
1
Sector connector
16
Motor connector
14, 15, 16
Other connector
2.3.
Salt water chlorinator contacts rep 13
Salt water chlorinator shut down when the pool is closed or when the closing is pending. The LED
rep12 indicates that the pool cover is closed.
2 contacts NC NO available to drive the shutdown relay of the salt water chlorinator. Dry contacts, free
from any potential. Max shut down power: 0.5A under 30Vdc.
The supply from chlorinator shall be a UL class2/PELV supply (<30Vdc).
77.5121.0001
The power supply cable (120Vac/60Hz) will be
jacketed in the field installation through metal
conduits. This accessories are not included. Tapped
hole ½"-14 NPT for the fitting.
To prevent the cable from slipping into the strain
relief, use a cable tie. (Accessories in supply)
Type
Removable, Tightening torque max 0.6 Nm
(0.44 ft lb) max, screwdriver
3.5mmx0.5mm
Tightening torque max 1.5 Nm (1.1 ft lb),
screwdriver 5x125
Removable, 0.6 Nm max, screwdriver
3.5x0.5
(1/29/2021)
ENGLISH
.
Stripping
Max
length
section
7 mm
2.5 mm²
(0.276 in)
15AWG
10 mm
12 mm²
(0.394 in)
6AWG
7 mm
2.5 mm²
(0.276 in)
15AWG
9/24