Software Class – Class A.
Control functions which are not intended to be relied upon for the safety of the
equipment
Overvoltage Category – Category III
Distribution Level. Fixed wiring and associated equipment (not electrical loads)
connected to the primary supply level, Category IV.
Pollution Degree – Pollution Degree 2
Normally, only nonconductive pollution. However, a temporary conductivity caused by
condensation may be expected. Deposits of moisture such as those that can occur from
expected condensation (e.g. the interior of a refrigerated compartment) or defrost water
are not anticipated.
Maximum Phase to Ground voltage of the supply source – 150 Vac
Protection against electric shock class - Class I
Grounded Equipment Applications/ Intended for use in grounded Equipment
Applications.
Environmental –
Indoor or Outdoor use. Raintight enclosure.
Classe de logiciels - Classe A.
Fonctions de contrôle qui ne sont pas destinées à être utilisées pour la sécurité de
l'équipement.
Catégorie de surtension - Catégorie III
Niveau de distribution. Câblage fixe et équipements associés (pas de charges
électriques) connectés au niveau de distribution primaire, catégorie IV.
Degré de pollution - Degré de pollution 2
Normalement, seule la pollution non conductrice. Cependant, on peut s'attendre à une
conductivité temporaire causée par la condensation. Les dépôts d'humidité tels que
ceux qui peuvent se produire en raison de la condensation attendue (par exemple, à
l'intérieur d'un compartiment réfrigéré) ou de l'eau de dégivrage ne sont pas prévus.
Tension maximale entre la phase et la terre de la source d'alimentation - 150 Vac
Classe de protection contre les chocs électriques - Classe I
Applications d'équipement mis à la terre/ Destiné à être utilisé dans des applications
d'équipement mis à la terre.
Environnement -
Utilisation à l'intérieur ou à l'extérieur. Enceinte étanche à la pluie.