4.2.
About the PLC display
COVER position:
100%: the pool is open
0%: the pool is closed
4.3.
Error messages :
Sensor error
The signal of the revolution Counter card sensor does not change of
state.
The motor is bloqued. Only a new initialisation (see 1st
control box programming) can allow the system to restart.
-
Check the connections
-
Change to manual mode, and check if the cover moves
-
In manual mode, check that there is tension between the
blue (0V) and the brown (+24Vdc) wires
Overcurrent
The electronic circuit breaker has stopped the motor: current
consumed more than 10 A.
It indicates that the motor is overcharged (l>10A), contact your
retailer. If this error occurs three times on the same open or close
cycle, the display shown on the adjacent figure will blink.
Press the On-Off switch on the box to reinitialise the system
Cycle error
The motor is supplied without interruption during 10 minutes.
The movement is interrupted and the motor is stopped during 20
seconds.
No movement can be done during that period.
77.5121.0001
Motor Current consumption
State: opening/closing/stop
(1/29/2021)
Motor speed
The key symbol indicates that
the PLC is locked (normal
position)
ENGLISH
13/24