4.3. Deleting the transmitter
In delete mode, individual transmitters can be deleted from the memory of an output.
If a transmitter is programmed in several outputs, it must be deleted individually from each output as neces-
sary. If an attempt is made to delete a transmitter that is not programmed into the selected output, the LEDS
flash quickly and the receiver remains in delete mode.
Step
Operation
1
Start the programming mode
2
Select operating mode L
(delete mode)
3
Select output.
P
P
Only one output can be selected.
Output can be changed as often
as required
4
Start the delete mode
(If you want to cancel 1x P < 1.6 s)
5
Send the transmission code to
delete the transmitter from the
selected output
4.4. Resetting an output
A separate reset can be carried out for each output.
All programmed transmitters are deleted and all switching times for the respective output are reset.
Step
Operation
1
Start the programming mode
2
Select operating mode L (delete
mode)
3
Select output.
P
P
Only one output can be selected.
Output can be changed as often as
required
4
Start the delete mode
(If you want to cancel 1x P < 1.6 s)
5
Send the transmission code to
delete all transmission codes from
the selected output and to reset
the TIMER
4.5. Resetting to factory settings
If you reset to factory settings, all settings of all outputs will be reset to the factory settings. All programmed
transmitters are deleted and all switching times are reset to the initial value.
Buttons to press
Start factory reset
Press and hold
P
simultaneously using 3 fingers
5. SPECIFICATIONS
Frequency
868.30 MHz
Modulation
FSK
Protocol
Easywave
Power supply
230 V AC 50 Hz
Circuit breaker
maximum MCB rating 10 A*
Output
2 potential-free contacts max. 10 A (1 x two-way and 1 x single pole)
Power consumption
0.9 W standby
max. 2.3 W without load
Maximum load
see § 6
Protection degree
IP66
Operating temperature
-20 °C to +45 °C
Dimensions (W/L/H)
180 / 94 / 58 mm
Weight
447 g
* The MCB rating is limited by national installation rules.
6. LOAD TABLE
Load type
max. load
Capacitive load
Dimmable LED lamps
2 A / 400 VA
Ohmic load
Incandescent lamps, 230 V
10 A / 2300 VA
halogen lamps etc.
EN
4
Button to press
Display
1x briefly or
LED 2TB flashes
P
M
CH1 CH2
2x briefly
LED 1TB flashes
repeatedly
P
M
CH1 CH2
L
or
LED CH1 or LED CH2 and
M
M
CH1 CH2
CH1 CH2
LED xTB flash.
until (> 1.6 s)
LED output and 2TB and 1TB
P
M
CH1 CH2
flash quickly
Transmitter button
LED output and 2TB and 1TB
Tx 1x briefly
light up.
When all the LEDs go out, the
receiver is ready for operation
Button to press
Display
1x briefly or
LED 2TB flashes
P
M
CH1 CH2
2x briefly
LED 1TB flashes
repeatedly
P
M
CH1 CH2
L
or
LED CH1/CH2 and LED xTB
M
M
CH1 CH2
CH1 CH2
flash
until (> 1.6 s)
LED output and 2TB and 1TB
P
M
CH1 CH2
flash quickly
until (> 1.6 s)
LED output and 2TB and 1TB
P
M
CH1 CH2
light up.
When all the LEDs go out, the
receiver is ready for operation
Display
+ press
+
P
P
M
CH1 CH2
M
M
CH1 CH2
CH1 CH2
shows for 4 s.
If the display is off, the
receiver is ready for operation
Inductive load
Halogen lamps with wound
3 A / 690 VA
transformers (transformer at least
85 % loaded)
Non- or serial-compensated fluo-
3 A / 690 VA
rescent lamps with ferromagnetic
ballasts
Parallel-compensated fluorescent
3 A / 690 VA
lamps with ferromagnetic ballasts
ECG
Electronic control gear, electronic
4 A / 920 VA
transformers etc.
EN
Warnings regarding installation
The installation of products that will permanently be part of the electrical installation and which include dangerous
voltages, should be carried out by a qualified installer and in accordance with the applicable regulations. This
user manual must be presented to the user. It should be included in the electrical installation file and it should be
passed on to any new owners. Additional copies are available on the Niko website or via Niko customer services.
EN
CE marking
This product complies with all of the relevant European guidelines and regulations. For radio equipment Niko llc
declares that the radio equipment in this manual conforms with the 2014/53/EU directive. The full text of the EU
declaration of conformity is available at www.niko.eu under the product reference, if applicable.
EN
Environment
This product and/or the batteries provided cannot be disposed of in non-recyclable waste. Take your discarded
product to a recognised collection point. Just like producers and importers, you too play an important role in
the promotion of sorting, recycling and reuse of discarded electrical and electronic equipment. To finance the
rubbish collection and waste treatment, the government levies recycling charges in certain cases (included in
the price of this product).
Support & contact
nv Niko sa
Industriepark West 40
9100 Sint-Niklaas, Belgium
www.niko.eu
EN
+32 3 778 90 80
support@niko.eu
PM005-33600R23061

Publicité

loading