Assembly and mounting instructions
General
Safety edge
1
Safety instructions
– These assembly and mounting instructions must be read completely
before starting work and must be kept for future reference.
– The assembly, mounting, modification or retrofitting of safety edges
and the commissioning of pressure-sensitive edges may only be
undertaken by persons who have completed relevant professional
training and have been authorised to carry out such work.
– To ensure effective operation of the protection system, the persons
2
Component overview
End cap
Contact end piece
Contact profile
Mounting profile
Connection cable
Resistor plug
8.2 kOhm
Control unit
Total length of the assembled safety edge
Length of the contact profile and mounting profile:
Total length minus 24 mm
Safety edges
EDGH 44X49, EDGI 44X74, EDGL 44X99
– Pressure-sensitive edges are pressure-sensitive protection systems.
They are specified in accordance with and meet the requirements of
standard EN ISO 13856-2 (see the declarations of conformity).
– Pressure-sensitive edges consist of a safety edge (sensor) and a
control unit. Safety edges are active switching profiles. They are
made from flexible rubber and mounted on metal mounting profiles.
– These installation instructions describe the assembly and mounting
of safety edges in the series EDGH 44X49, EDGI 44X74, EDGL 44X99.
undertaking these tasks will also need to have knowledge of the
product-specific guidelines and standards that apply on the site where
the pressure-sensitive edges are being used. An example of an
applicable standard would be EN 12978 – Safety devices for pow-
er-operated doors and gates.
– Failure to comply with these safety instructions may result in severe
or fatal injury and serious damage to property.
= L
total
9