3. Intermediate check / Resistance measurement
Connect the resistor plug and the cable, actuate the sensor
at several points
3.5
Preparing the mounting profile
Cutting the mounting profile to length
L
total
12
Sensor actuated: ≤ 500 ohm
Sensor not actuated with 8.2 kOhm resistor plug: resistance between 8.0 and 9.0 kOhm
= total length of the sensor
Metal saw
90 ˚
L
= L
– 24 mm
mounting profile
total
Ω