SM 2610912724 3/03
3/6/03
HOLE SAWS
Keep hands away from
WARNING
!
cutting area and hole saw.
Keep your second hand on the side
handle or motor housing. If both hands are
holding the drill, they cannot be cut by the
Service
Preventive maintenance
WARNING
!
performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could cause serious hazard. We
recommend that all tool service be
performed by a Skil Factory Service Center
or Authorized Skil Service Station.
TOOL LUBRICATION
Your Skil tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARBON BRUSHES
The brushes and commutator in your tool
have been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend
every two to six months the brushes be
examined. Only genuine Skil replacement
brushes specially designed for your tool
should be used.
BEARINGS
After about 300-400 hours of operation, or at
every second brush change, the bearings
If an extension cord is
WARNING
!
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-
wire extension cords that have 3-prong
plugs and receptacles.
NOTE: The smaller the gauge number, the heavier
the cord.
All manuals and user guides at all-guides.com
2:00 PM
Page 10
hole saw. Hold the drill firmly to prevent loss
of control. Unplug drill when removing core.
Hole saws are Ideal for use with lock
installation kits for 2-1/8" deadbolts or
locksets with 15/16" or 1" latch hole in
wooden and composition doors.
Maintenance
should be replaced at Skil Factory Service
Center or Authorized Skil Service Station.
Bearings which become noisy (due to heavy
load or very abrasive material cutting) should
be replaced at once to avoid overheating or
motor failure.
WARNING
!
the power supply before cleaning or
performing any maintenance. The tool may
be
cleaned
compressed dry air. Always wear safety
goggles when cleaning tools with
compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through openings.
CAUTION
!
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents,
detergents that contain ammonia.
Accessories
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Rating
Cord Length in Feet
25
3-6
18
6-8
18
8-10
18
10-12
16
12-16
14
-10-
Cleaning
To avoid accidents always
disconnect the tool from
most
effectively
with
Certain cleaning agents
and solvents damage
ammonia
and
household
Wire Sizes in mm
Cord Length in Meters
50
100 150
15
30
60
120
16
16
14
.75 .75 1.5
2.5
16
14
12
.75 1.0 2.5
4.0
16
14
12
.75 1.0 2.5
4.0
16
14
12
1.0 2.5 4.0
—
12
—
—
—
—
—
—
2