TROUBLE-
SHOOTING
101487
All manuals and user guides at all-guides.com
Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.
OBSERVED FAULT
Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.
Heater will not
ignite, but motor runs
for a short period of
time.
Motor does not start
when heater is
plugged in, fan
rotates slowly or
does not turn.
WARNING
POSSIBLE CAUSE
Wrong pump pressure
Dirty air output, air intake,
and lint filters
Dirty fuel filter
Dirt in nozzle
Dirty photocell lens
Bad flame-out control
Wrong pump pressure
Carbon deposits on spark
plug and/or improper gap
Dirty fuel filter
Dirt in nozzle
Water in fuel tank
WARNING: High voltage!
Electronic ignitor not
grounded (earthed)
Bad electronic ignitor
Flame-out control not reset
Binding pump rotor
REMEDY
See Pump Pressure
Adjustment, page 12.
See Air Output, Air Intake
and Lint Filters, page 11.
See Fuel Filter, page 10.
See Nozzle, page 12.
Clean photocell lens.
Replace flame-out control.
See Pump Pressure
Adjustment, page 12.
See Spark Plug, page 11.
See Fuel Filter, page 10.
See Nozzle, page 12.
Drain and flush fuel tank
with clean kerosene. See
Storage, page 8.
Make sure electronic
ignitor mounting is tight.
Replace electronic
ignitor.
Reset flame-out control
button, see Figure 4,
page 7.
If fan is hard to turn, see
Pump Rotor, page 13.
9