Installation
1
Frame Mounting
Typical installation is shown. It may be necessary to repair the wall
after mounting. The fixture may not cover all of the wall modifications.
16"
(406mm)
centers
13"
(330mm)
A
Finished Floor
Bradley • 215-1778 Rev. K: ECO 20-08-045
A
The frame and the bowl
must be adequately
supported.
Drywall
Fasteners (supplied by installer)
to secure backing to studs
D
Use 3/8" fasteners and square washers
provided to secure the frame to the backing
(5) places. Shim frame as necessary.
Support Backing Mounting
Height
Standard Height, ADA, and TAS
ADA, Juvenile and TAS, Grades
6 thru 12
Drain, supplies and electrical box are
shown in their approximate locations.
B
Cut clearance holes in the backing as
required.
NOTE: Backing should equal the
thickness of the drywall (1/2" minimum).
26"
(660mm)
8/25/2020
LVLD2
"A" Dimension
20" (508mm)
17" (432mm)
If needed, shim the
C
frame at anchor points to
ensure the offset bracket
is straight. Leave the
top screw loose for bowl
installation.
7