Télécharger Imprimer la page

Dea LIVI 403E-6NET Notice D'emploi Et Avertissements page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating instructions and warnings
WARNING Wrong assessment of impact forces may cause
serious damage to people, animal and things. DEA System re-
minds all personnel that the installer must ascertain that these
impact forces, measured according to EN 12445 prescriptions,
are actually below the limits indicated by EN14453 regulation.
WARNING In line with EU Directive 2002/96/EC for waste
electrical and electronic equipment (WEEE), this electrical pro-
duct must not be disposed of as unsorted municipal waste.
Please dispose of this product by returning it to your local
municipal collection point for recycling.
3 MODELS AND CONTENTS
OF THE PACKAGE
The name LIVI identifies a series of electromechanical opera-
tors with different features as to motor and control board power
supply voltage, range of built-in or external control board and
mechanical adjustment of force, electronic clutch and built-in
limit switch. DEA System articles in the series are listed in the
"AVAILABLE MODELS" table. LIVI is completed by a set of acces-
sories listed in the "PRODUCT ACCESSORIES" table.Inspect the
"Contents of the Package" on Page 30 and compare it with your
product for useful consultation during assembly.
4 OPERATING INSTRUCTIONS
In compliance with Directive 2006/42/CE Enclosure I, Point
1.7.4.
4.1 Product description
LIVI is an electro-mechanical operator designed for the
automation of sliding gates. LIVI is basically made up of a
mechanical gear motor (vedi F1 pag. 30) rotating the draft
gear that, in association to a properly installed rack, converts
the circular movement of the gear motor into straight-line
movement, thus allowing the gate to move in its own slide.
4.2
Technical data
See the "TECHNICAL DATA" table.
4.3
Labelling information
Part of the summarised data for the CE label are listed in the
label applied to the product (see Position F5, Page 30); the data
regarding the seller are found in the enclosed Warranty, whi-
le "Indispensable Operating Safety Elements" are found under
Point "4.2 Technical data".
8
Motor power supply voltage (V)
Absorbed power (W)
Max Thrust (N)
Work cycle (leaf L=5m)
Max n° of operations in 24 hour
(leaf L=5m)
Built-in capacitor (µF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening speed (m/min)
Weight of product with package (Kg)
Protection degree
L I V I
All manuals and user guides at all-guides.com
4.4
The LIVI is designed for installation in sliding gates as an
actuator for the operational automatism as shown in F3 on Page
31. Brackets for both "horizontal" (standard) and "vertical" (see
"PRODUCT ACCESSORIES" table) installation have been arran-
ged for. The LIVI has been designed and tested for operation
under "normal" civil gate opening conditions; temperature li-
mits, degrees of protection against dust and water, and other
data are provided in Point 4.2 "Technical Data". Satisfactory
operation requires the correct positioning of the LIVI operator
with respect to the gate; DEA System recommended measure-
ments are shown in F3 page 31. The automatism required must
be selected according to the gate to be moved; the attrition on
the attachments, the weight, the length/height of the gate wing,
and the degree of closing of the surfaces are the elements to be
considered.
WARNING The use of the product under unusual conditions
not foreseen by the manufacturer can create situations of dan-
ger, and for this reason all the conditions prescribed in these
instructions must be respected.
WARNING Under no circumstances must the product be
used in explosive atmospheres or surroundings that may prove
corrosive and damage parts of the product.
403E - 6NET
803E - 9NET
230 V ~ ±10% (50/60 Hz)
320
340
18 cycles/hour
11 cycles/hour
60
8
140 °C
11
"PRODUCT ACCESSORIES" table
Article
Description
Code
111
619000
112
126001
113
126000
460
619010
Appropriate conditions of use
5/24NET/F
450
80
490
210
22 cycles/hour
40
60
12,5
-20÷40 °C
160 °C
10
12,5
IPX4
Nylon rack
Zinc plated rack
22x22
Zinc plated rack
30x12
Foundation base
to be cemented
8/24NET/F
24 V
110
260
18 cycles/hour
40
-
-
12

Publicité