11.0 minimum combustible mantel clearances
WARNING
!
•
Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with these
instructions may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top,
vent, mantel, front, etc.) are clearly maintained.
•
When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
•
Installing a television or other electronics above the appliance may cause discolouration, melting, or damage
to the electronics. Use clearances as guidelines and refer to your TV manufacturer's instructions for further
information.
MANTEL DEPTH
12" (30.5cm)
MANTEL HEIGHT
2" (5.1cm)
Top of
finishing
flange
25 11/16" (65.2cm)
A
2" (5.1cm)
Optional hearth
extension
Bottom of
the unit
Electronics, picture frames, decors, or other wall-
mounted objects must be 6" below the air outlet
opening and 6" above the finishing flange.
All manuals and user guides at all-guides.com
finish framing - after appliance installation
Installing a mantel between this appliance and
electronics or other materials that may be sensitive
to heat, will reduce the effect of direct heat on them.
Follow mantel height and depth instructions for proper
clearance information. A non-combustible mantel is
considered a non-combustible protrusion
Bottom of
finishing flange
Air outlet opening
Ceiling
6" min.
6" min.
W415-1739 / C / 08.03.17
EN