7.0 rough framing - before appliance installation
finish framing - after appliance installation
EN
Before framing your appliance, determine vent requirements before deciding the final location of the appliance.
After rough framing, place the appliance in its final position. Also, see appliance manual for vent shield installation,
nailing tabs installation,electrical installation, gas installation, etc.
single-sided
Ref
20 1/8" (51.1cm)
E
F
53 13/16" (136.7cm)
J
73" (185.4cm)
L
see-thru
Ref
E
16 3/16" (41.1cm)
53 13/16" (136.7cm)
F
J
L
73" (185.4cm)
16
W415-1739 / C / 08.03.17
All manuals and user guides at all-guides.com
L
E
F
J
LV38-1
LV50-2
20 1/8" (51.1cm)
65 13/16" (167.2cm)
Optional - Appliance does not need to be elevated above floor
73" (185.4cm)
E
F
LV38-1
LV50-2
16 3/16" (41.1cm)
65 13/16" (167.2cm)
Optional - Appliance does not need to be elevated above floor
73" (185.4cm)
Before framing the appliance, ensure to install
the firestop first as it will not fit between the
studs if installed after framing.
note:
Although the minimum enclosure
height for the LV series is 73",
some venting configurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.
LV62
20 1/8" (51.1cm)
77 13/16" (197.6cm)
91" (231.1cm)
Before framing the appliance, ensure to install
the firestop first as it will not fit between the
studs if installed after framing.
note:
Although the minimum enclo-
sure height for the LV series is
73", some venting configurations
that require more vertical rise will
L
require a larger enclosure to pro-
vide minimum vertical clearance
between vent pipes and combus-
tibles.
J
LV62
16 3/16" (41.1cm)
77 13/16" (197.6cm)
91" (231.1cm)
LV74
20 1/8" (51.1cm)
89 13/16" (228.1cm)
91" (231.1cm)
LV74
16 3/16" (41.1cm)
89 13/16" (228.1cm)
91" (231.1cm)