6.0 minimum clearance to combustible enclosures
minimum clearance to combustible enclosures
EN
single-sided
1" [25mm] minimum
to sides for vertical
venting.
When passing through
a ceiling, use firestop
spacer W500-0028
(not supplied)
0" to side standoffs
1/2" finishing flange
0" to bottom of the
appliance
minimum clearance
Ref
L
73" (185.4cm)
note:
The LV series requires a minimum inside enclosure height of 73" measured from the bottom of the appliance.
For temperature requirements, this area must be left unobstructed. It is mandatory to ventilate the enclosure
according to these instructions.
Although the minimum enclosure height for the LV series is 73", some venting configurations that require more
vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and com-
bustibles.
14
W415-1739 / C / 08.03.17
All manuals and user guides at all-guides.com
L
LV38-1
LV50-2
73" (185.4cm)
6" [152mm] minimum
3" [76mm] to top
2" [51mm] to sides /
bottom
When passing through
a wall, use firestop
spacer assembly
W010-4178 (supplied)
0" to non-combustible
finishing such as brick
and stone. When using
non-combustible finish-
ing, only use firestop
spacer (W615-0162)
included in the firestop
assembly (W010-4178)
0" to back standoffs
firestop spacer
(W615-0162)
LV62
91" (231.1cm)
91" (231.1cm)