Installation
8
Adjust Temperature with Water Running
This valve is NOT factory preset.
Upon installation, the temperature
of this valve must be checked and
adjusted to ensure delivery of a
safe water temperature. Water
in excess of 110°F (43°C) may
cause scalding.
9
Trap Cover
Make all connections before installing trap cover.
Hang the trap cover onto
A
the hook, then secure the
trap cover with the screws
provided, starting with the
side screws.
Bradley • 215-1779 Rev. G: ECN 19-08-037A
All manuals and user guides at all-guides.com
A
Loosen Cap Screw about 1/4" (4-6
turns) and lift up cover (do not
remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
Finishing
Washer
Hook
Washer
#10-24
Screw
#10-24
Flat Head
Screw
2/27/2020
LVLD3
C
H
11