Formular for documentation of the setting parameters
Device:
Device No:
Configurated by:
Date:
1.
Parameterization
1.1 Lim. dir. of rot.
Frequency mode 1
Monitoring function 1
f-limits 1
Upper limit 1
Lower limit 1
Direction of rotation 1
Frequency mode 2
Monitoring function 2
f-limits 2
Upper limit 2
Lower limit 2
Direction of rotation 2
Frequency mode 3
Monitoring function 3
f-limits 3
Upper limit 3
Lower limit 3
Direction of rotation 3
Frequency mode 4
Monitoring function 4
f-limits 4
Upper limit 4
Lower limit 4
Direction of rotation 4
Esc
1.2 Hysteresis
Esc
1.3 Time Delay
Start-up delay
Reset delay
Alarm delay
Changeover bridging
Esc
Please cut off and file it !
UH 6937
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overfrequency
Underfrequency
Inside range
Outside range
f-monitoring off
Hz
Hz
Clockwise rotation
Anticlockwise rot.
Direct. of rotat. off
Overfrequency
Underfrequency
Inside range
Outside range
f-monitoring off
Hz
Hz
Clockwise rotation
Anticlockwise rot.
Direct. of rotat. off
Overfrequency
Underfrequency
Inside range
Outside range
f-monitoring off
Hz
Hz
Clockwise rotation
Anticlockwise rot.
Direct. of rotat. off
Overfrequency
Underfrequency
Inside range
Outside range
f-monitoring off
Hz
Hz
Clockwise rotation
Anticlockwise rot.
Direct. of rotat. off
%
s
s
s
s
1.
1.4 Tol. dir. of rot.
Start up tolerance
Alarm tolerance
Switchover tolerance
Esc
2)
1.5 Alarm memory
3)
Alarm memory
Automatic reset
Esc
1.6 Muting function
Activate
Deactivate
Esc
Esc
1.7 Ext. settings
Min. frequency for
direction of rotation
2)
Discrepancy time
3)
Esc
Esc
Parameterization Using the Display
To enter the device's parameterization mode the following key combination
is provided:
Press and keep pressed the right key at first. Then, press the left key (see
below). A display test follows and has to be acknowledged using the OK
key (right key) when it was successful. Then, it is possible to change the
parameterization. Before the device adopts changed parameters, they must
1)
be confirmed once more for safety reasons.
2)
3)
Current status:
E2: 100Hz, E3: 100Hz
Clockwise rotation
Frequency mode 1
2)
ü
3)
OK
2.
OK
Only available at variant /_ _1.
1)
2)
Not available at monitoring function „underfrequency".
1)
Not available at monitoring function „overfrequency".
3)
OK
55
Period(s)
Period(s)
Period(s)
Hz
s
1.
M11262_b
UH 6937 / 30.05.22 de / en / fr / 551A
1)
OK
OK
1)
OK
OK
OK
OK