schmalz Pompe X SXPi15 Notice D'utilisation page 85

Table des Matières

Publicité

Parameter
SPDU Index
dec
hex
Identification
7
0x07
Vendor ID
8
0x08
9
0x09
Device ID
10
0x0A
11
0x0B
16
0x0010
Vendor name
17
0x0011
Vendor text
18
0x0012
Product name
19
0x0013
Product ID
Product text
20
0x0014
Serial number
21
0x0015
22
0x0016
Hardware revision
23
0x0017
Firmware revision
Online
64
0x0040
System vacuum
65
0x0041
System pressure
Initial Setup
68
0x0044 ctr
Air saving function
69
0x0045 bLo
Blow-off mode
70
0x0046 o-1
Output 1 function
71
0x0047 o-2
Output 2 function
72
0x0048 o-3
Output 3 function
73
0x0049 tyP
Signal type
Vacuum display unit
74
0x004A uni
75
0x004B dLY
Output filter
J. Schmalz GmbH
Data
Parameter
width
2 bytes
3 bytes
15 bytes
15 bytes
32 bytes
17 bytes
30 bytes
9 bytes
3 bytes
3 bytes
2 bytes
0 - 999
2 bytes
0 - 999
1 byte
0 - 2
1 byte
0 - 2
1 byte
0 - 1
1 byte
0 - 1
1 byte
0 - 1
1 byte
0 - 1
1 byte
0 - 2
1 byte
0 - 3
Value range
Access
Default value
0x00
ro
0xEA
0x01
ro
0x87
0x73
ro
J. Schmalz GmbH
ro
www.schmalz.com
ro
SXPi_PC
ro
10.02.02.00000/00
ro
SXMPi 00 IMP Q PC 2xM12 Order-Code
ro
000000002
ro
ro
ro
0
ro
0
rw
1
rw
0
rw
0
rw
0
rw
0
rw
0 / 1
rw
0
rw
1
2 von 5
Remark
0x00EA = 234 = J. Schmalz GmbH
Internal code number
Manufacturer designation
Internet address
General product name
Order-Nr.
Serial number
Hardware revison
Firmware revision
Unit: mbar
Unit: 1 mbar x 10
0 = not active (off)
1 = active (on)
2 = active with supervision (onS)
0 = Externally controlled blow-off (-E-)
1 = Internally controlled blow-off – time-dependent (I-t)
2 = Externally controlled blow-off – time-dependent (E-t)
0 = NO
1 = NC
0 = NO
1 = NC
0 = NO
1 = NC
0 = PNP
1 = NPN
0 = mbar
1 = kPa
2 = inHg
0 = Off
1 = 10ms
2 = 50ms
3 =200ms
SXPi_SXMPi_V2 Data Dictionary 21.10.01.00061_01 2014-07-29.xls