PROTECTION FROM ELECTRIC SHOCKS
According to EN 61010-2-032 - 600 V CAT III - Pollution degree 2.
ELECTROMAGNETIC COMPATIBILITY
According to EN 61326-1
LIMIT OF THE NON DESTRUCTIVE PEAK CURRENT AS A FUNCTION OF THE
FREQUENCY
Ip (A peak)
140
100
50
0
10
Max. cable dimensions: ∅ 11.8 mm
Jaw opening: 12.5 mm maximum
Dimensions: 231 x 67 x 36 mm
Twin core lead (coaxial) 2m ended by
a BNC plug insulated and moulded
Weight: 330 g with battery
PROTECTIONS:
Degrees of protection: IP 20 to IEC 529
Protection from shocks: 100 G, 6 ms, half-cycle, to IEC 68-2-27
Drop height from all angles: 1 m
Resistance to vibrations: 10/55/10 Hz 0.15 mm, to IEC 68-2-6
Bumps: 40 G, 6 ms, 4000 bumps, to IEC 68-2-29

ELECTRICAL SAFETY

100
1000

MECHANICAL SPECIFICATIONS

15
10000
F(Hz)
231
Sizes
in mm