5.
Programming
5.1
Configuration
Tab. 1: Setting the parameters
Function
(factory setting)
Use as
(factory setting)
Direct adjustment
(Nominal room
value)
Room device RGB
The setting level will be called by pressing the presence button for
a long time. The parameters are selected by pressing the presence
button for a short time. Programming is ended by pressing the ope-
ration mode button.
Setting
ru = 1
The room device is addressed as RG 1 (for heating circuit 1).
ru = 2
The room device is addressed as RG 2 (for heating circuit 2).
P1 = 1
Storage is carried out automatically:A correction of the
nominal value is taking over by operating the operation
mode button as well as without further confirmation (Time-
out).
P1 = 2
Storage is carried out after confirmation.A nominal value
correction is only carried out after confirmation by the ope-
rating mode button.
Detailed information for programming the integrated system con-
trol RVS and setting tables with the programmable parameters is
given in the Installation Manual of the boiler (e.g. room influence
RGB).
Programming
GB
35