3.4
Channel 3
Mini maxi adjustment
Adjustment accuracy
± ( % output + offset)
Regulation / Load 10 – 90%
Ripple (BP 20 MHz)
Power / Current
Accuracy measurement (25°C ±5°C)
± ( % output + offset)
3.5
Functions
Against short-circuits
Against over-temperature
Against over-current on main source
Remote sensing
Memory
Functions accessible by keypad
3.6
Other caracteristics
Alimentation (Entrée secteur)
Maximum power consumption
Internal fuses (x2) AC input
Efficiency
Safety
CEM
Voltage on the earth
Operating/Storage temperature
Humidity condition
Altitude
Db level of fan
Dimensions
Weight
4000 4 361_09/22
Tension
OVP (over voltage programming)
Voltage
Constant voltage
Constant voltage
Max power = 15W
Current
By current regulation
By fan and thermal circuit-braker
By internal fuse (T4A ; 250V ; 5x20)
4 wire mode, Disconnect scribe terminal blocks for 0,5mm² wires
Storage
Recall
6 available
In Voltage or Current (channel 1 & 2)
220 – 240 Volts ±10%, 50 – 60 Hz
EEC socket C14 for cable 2 poles + earth C13 (2P + E)
475W (5W in Standby mode)
5 x 20 ; 250V T4A
> 81% of the maxi powerful
Class I, CAT II, degree of pollution 2
Complies with EN 61010-1, CAT II
Complies with EN 61326-1 & EN 55011
± 150 Vdc
0°C to + 40°C / -20°C to + 60°C
< 85% to 30°C and decrease to 50% at 40°C
< 2000 m
< 48dB
111 mm x 210 mm x 260 mm
3 kg
20
1 à 15,00 Volts (0 à ±10mV)
0 à 15,3 Volts
0.07% + 10 mV
< 20 mV
≤ 1 mVrms ; Bruit ≤ 10 mVpp
≤ 15 mVpp Pics de commutation
Max current = 3A
0.03% + 10 mA
15 configurations
16 (1 no configurable)
SQUARE,ARBITRARY
RAMPE positive and negative
Periodic or Multi shot
ENGLISH