6. INSTALL UPPER FLUE MOUNTING BRACKET (DUCTED INSTALLATION ONLY)
Center the upper flue mounting bracket with the center line
previously drawn in step 5 and place it flush with the ceiling.
Use the upper flue mounting bracket as a template to mark the
position of its screws.
Drill the 3 screw holes using a 3/16" drill bit.
Insert the included drywall anchors into the drilled holes (one per
hole).
Secure the upper flue bracket to the wall using 3 no. 8 x 3/4"
screws.
Make sure that the bracket is tight against the wall.
7. INSTALL THE HOOD
BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.
DO NOT REMOVE the protective plastic film covering the decorative flue (upper & lower) and the hood yet.
1. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it securely engages the bracket.
2. Level the hood.
3. With the hood hanging in place, secure it to the wall through
both holes located in the inside upper back of hood using
2 no. 8 x 1½" screws.
4. Drill through both holes located in the inside lower back of
hood using a 3/16" drill bit. Insert the included drywall anchors
into the drilled holes (one for each hole). Secure the hood to
the wall using 2 no. 8 x 3/4" screws and 2 washers.
8. INSTALL ANKWT32 NON-DUCT KIT (NON-DUCTED INSTALLATION ONLY)
Refer to the installation sheet included with the non-duct kit for details.
Once the non-duct kit installation is done, go to step 13 to finalize the hood installation.
9. INSTALL ADAPTER/DAMPER (SINGLE BLOWER MODELS ONLY)
Mount the 8" round adapter/damper (included in a separate box) to the hood using
4 no. 8 x 3/8" sheet metal screws (included).
C
EILING
HD0377
S
CREW LOCATIONS
!
WARNING
CAUTION
S
IDE VIEW
HD0378A
- 7 -
C L
M
OUNTING BRACKET
FLUSH WITH CEILING
U
PPER HOLES LOCATION
B
ACK OF THE HOOD
Ø 7/32"
L
OWER HOLES LOCATION
HJ0042
.
TYP