By adjusting the curve to 0 the Sliding Temperature is disabled.
The system must be adjusted during installation by qualified personnel. The user can still make further adjustments for better
comfort. If the room temperature is lower than the desired value, it is advisable to set a higher order curve and vice versa. Proceed
by increasing or decreasing in steps of one and check the result in the room.
Once the Compensation curve is set, it is possible to adjust the parallel offset of curves from 20 to 40 as shown in the following
graphs:
External temperature
1. Press the button for 3 seconds.
2. The display shows parameter CU.
3. Press the button until parameter OF is displayed.
4. Press the buttons
parallel offset of curves in 1°C increments. By
EN
128
/
to modify the
code 3541Z230 - Rev. 05 - 12/2021
External temperature
keeping the button pressed the value will change
rapidly.
5. Press any other button to exit the menu.