Pump/Control Access
34" (86.4 cm) W x
15" (38.1 cm) H Min.
2-1/4"
42" (106.7 cm)
(5.7 cm)
1-1/2" O.D.
Product Information
Bath whirlpool with Relax
Package
Fixture:*
basin area
Bathing
50" (127 cm) x 29"
well
(73.3 cm)
water depth
To
16" (40.6 cm)
overflow
* Approximate measurements for comparison only.
Pump
Heater
1.5 HP
1.5 kW
Cut out template
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control
220-240 V, 20 A, 50/60 Hz
Locate the outlet behind the whirlpool and within 24" (61 cm)
of the pump.
Installation Notes
NOTE: Pump protrusion beyond rim.
Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of
1850 lbs. (839.1 kg).
1023241-1-C
All manuals and user guides at all-guides.com
3" (7.6 cm) x 24"(61 cm)
Flat Faucet Deck
K-1375-CT
shown
top area
61" (154.9 cm) x
32" (81.3 cm)
capacity
100 gal. (378.5 L)
Voltage
Frequency
Amperage
240 V
50/60 Hz
11 A
113311-7
2-1/2"
Note: Pump/piping protrudes beyond rim.
(6.4 cm)
36" (91.4 cm)
72" (182.9 cm)
3" (7.6 cm)
Hot water supply should be 70% of capacity or greater.
Installations will vary.
If installing a rim mount faucet, make sure there is no interference
with drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
weight
requirements if installing a spout on the faucet deck.
135 lbs.
Fixture conforms to ANSI Standard Z124.1. All dimensions are
(61.2 kg)
nominal.
2
No change in measurements with drain
shown. (K-7161-AF or K-7161M-AF)
Recommended faucet area.
13-1/2"
(34.3 cm)
6-1/2" (16.5 cm)
3-1/2"
(8.9 cm)
22"
(55.9 cm)
2-7/8" (7.3 cm)
Kohler Co.