Wireless motion sensor 868.3 MHz

Control elements

Operating mode switch

Using the operating mode switch you can determine what time of the
day the wireless motion detector is activated. The sensitivity of the sensor
to warmth and light will be adjusted to environmental conditions.
You have the following options:
Night mode
Day
Day + Night mode (24 h)

Sabotage switch

The sabotage switch notifies the BrematicPRO Gateway as soon as the
wireless motion detector is removed from the wall bracket. The sabotage
switch is intended to prevent misuse or the removal of the device by
strangers.

Pair button

By pressing the pair button, the device is put into pairing mode to link
the Home Automation Systems BrematicPRO via the BrematicPRO
Gateway.

Inserting / replacing the battery

The motion detector is operated using two 1.5 V batteries (type AA).
Raise the battery cover/installation plate from the recess using a
small screwdriver or a similar tool and lift it fully off.
If applicable, remove the drained batteries.
Insert the batteries into the battery compartment with correct
polarity. Please note the marking inside the battery compartment.
Close the installation plate until it audibly clicks into place after
you have paired the motion detector with the BrematicPRO System.
The motion detector is now ready for use.
Note: If the batteries are drained, the device LED will flash
once every second behind the sensor cover.
12 EN
2 x 1.5 V batteries (Type AA)

Installation without drilling

Note: Check before installation whether the product is located within
the range of the Gateway.
Use the adhesive pad to affix the wireless motion detector to
a suitable installation location without drilling.
Ensure that the installation area is clean, dust-free and free
of grease.
Avoid installation locations which are under the strong influence
of heat (i.e. sunlight) as the adhesive tape can come unstuck.

Installation using screws

Note: Check before installation whether the product is located within
the range of the Gateway.
CAUTION! DANGER OF ELECTRIC SHOCK!
Make sure that you do not damage electrical cables in the wall
during installation.
The device is equipped with an installation plate which allows
it to be assembled on a wall or ceiling.
Note: Do not orient the device directly towards windows, radiators
or other heat sources, as otherwise, a false alarm could be triggered.
Select a suitable installation position for the device in the room
to be monitored.
Note: The detection area of the sensor is approx. 130 ° with a
range of approx.10 metres at an optimal installation height of
2.5 metres.
Note: A lower installation height reduces the range.
Draw the three drill holes on the wall using a pen, with the help
of the installation plate.
Adhesive pad position