A System presentation
ZOE timer-thermostats are designed to work alongside
ZONING SYSTEM control units in order to control
temperature for up to 6 different zones.
The ZOE timer-thermostat communicates with the control
unit. The central unit manages one or several motorised
gates (which regulate the airflow), as well as starting up/
shutting down the climate control unit, which provides the
airflow.
B Technical characteristics
ZOE thermostat (transmitter)
Power with two 1.5 V LR06 AA batteries (alkaline).
Average battery life 1 year (or longer). The batteries are
supplied with the equipment.
Battery life indicator.
Carrier frequency (ISM band, Standard I-ETS 300-220):
433.34 MHz (Optional: 434.92 MHz)
Medium range: 50 m in free field, 20 m in habitat.
Operating temperature: 0ºC to 55ºC.
Storage temperature: -10ºC to 60ºC.
Wall mount with bolts (supplied).
Protection grade: IP 20.
Economy ECO mode (±3ºC setpoint temperature
variation).
Control unit (receiver)
Power 230 VAC, 50/60 Hz.
KSP consumption: 4 VA, KRCPLUS: 14 VA.
Medium range: 50 m in free field, 20 m in habitat.
Orientable external antenna.
Carrier frequency (ISM band, Standard I-ETS 300-220):
433.92 MHz (Optional: 434.33 MHz)
Work cycle <10%.
Receiver, Class III.
Protection grade: IP 20.
Electrical insulation protection, Class II.
Operating temperature: 0 ¬½C to 55¬½C.
Storage temperature: -10 ¬½C to 60 ¬½C.
MADEL ATD hereby declares that the KRCPLUS / KSP /
KFCPLUS units comply with the essential requirements
and any other applicable or obligatory provisions of
Directive 1999/5/EC.
Timer-thermostat ZOE
C Location of the thermostats (fig. 1)
Fig. 1 Location of the thermostats
Place the thermostat in a significant location.
Place at a height of approximately 1.5 m, avoiding direct
heat sources and unwanted air currents.
Avoid placing the thermostats close to metal masses
and conductor elements.
ZOE time thermometers are powered by batteries,
meaning connections are not necessary.
D Battery change (fig. 2)
When the thermostat display shows the low battery
indicator, you have approximately 2 weeks to make the
change.
Remove the front cover from the thermostat, pressing
the tab in the top with a thin pointed tool.
Change the batteries; use alkaline batteries for longer
life (LR06 AA).
Fig. 2 Battery change