Keys and indicators (fig. 3)

1
Setpoint/ambient temperature
2
Fan speed indicator
3
Clock indicator
4
Battery use indicator
5
Zone and Master indicators
6
Day of the week indicator
7
Timeslots indicator
8
Reduce temperature key
9
"FAN" key, fan speed
10 "PROG" key to enable/disable weekly programming
11 "ECO" key (economy mode ±3ºC)
12 "INFO" key, information on configuration
13 "SET" key, access to programming
14 "MODE" operation key (cold/heat/boiler)
15 Increase temperature key
16 "ON/OFF" key
17 Programming menu indicators
18 Thermostat OFF indicator
19 Operating mode indicators (cold/heat/boiler)
Fig. 3
F

Use

Configuration
Configuration by an accredited installer must be completed
before using the ZOE thermostat, as explained at the end
of this manual.
Turning the system on
The zoning system can only be turned on using the
MASTER thermostat, which is normally installed in the
most used site:
1 Press the "ON/OFF" key (16).
2 Select COLD / HEAT / BOILER operation mode (14).
3 Select the setpoint temperature using the keys "+" "-"
(15/8).
Conditioning the zones
Carry out the following steps for each of the thermostats:
1 Press the "ON/OFF" key.
2 Select the setpoint temperature ( "+" / "-" keys).
Turning off the zones
Specific zones are turned off from the corresponding
thermostat:
1 Press the "ON/OFF" key for each zone to be disabled.
12
User Manual
User Manual
18
17
16
15
14
13
12
Turning off the whole system
The complete system can only be turned off using the
MASTER thermostat:
1 Press the "ON/OFF" key twice until the display shows
the word OFF and MASTER appears underneath the
zone indicator. Indicates shutting down of the entire
facility.
Economy Mode
ECO mode changes setpoint temperature by ¬±3¬½C.
This is enabled in provisionally unoccupied zones, in order
to maintain a certain degree of comfort without excessive
energy consumption.
1 Press the "ECO" key (11) to enable and disable this
function.
Operation mode (winter/summer)
It can only be changed using the MASTER thermostat.
1 Press the key (14) to change from cold to heat, or vice
versa.
2 When commanding a boiler, place in the flame. The
MASTER thermostat will act as a heating thermostat
(only if the central unit so allows).
3 In equipment in which the machine-thermostat cannot
be replaced, the cold-heat cycle change must be carried
out on both the machine thermostat and the master
thermostat. The machine thermostat must always be in
demand in order to stop the climate control unit from
shutting down, with the zone thermostats taking over
temperature control.
V 03/16
3
19
1
2
4
5
ºC
ECO
Z
6
PROG
TIMER
SYST
ON
OFF
MASTER
1
2
3
4
5
6
7
7
2
4
6
8
10
12
14
16
18
20
22
24
8
9
SET
PROG
DAY
COPY
10
INFO
ECO
CLEAR
FRESH
11

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières