1.4
Technical Data
Model
Load capacity
Lifting time (2,000 kg)
Lowering time (2,000 kg)
Electrical system
Lifting height
Control voltage
Motor
Upstream fuse
Connection cable
Protection type
Working pressure ²
Recommended hydraulic oil
Oil quantity
Permissible sound level
Weight
Concreate requirements
Floor slope
If the indicated rated load cannot be lifted, please contact our
service team.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2021-09
ATH-Single Lift 25M
2,500 kg
3/400V/50 Hz
115-1870 mm
1 C 16 A / 3 C 16 A
Min. 3 x 1.5 mm² or 5 x 2.5 mm²
Approx. 180 bar
Summer: HVLP-D 46 (e.g.: ENI Precis HVLP-D 46)
Winter: HVLP-D 32
Approx. 6 l
Min. 250mm reinforced concrete C25
Manufacturer ATH-Heinl GmbH & CO.KG
- 9 -
60 s
60 s
DC24V
1.5 KW
IP 54
≤ 76 dB
900 kg
Max. 3°