Product Information
Flow temperature control
The flow temperature changes according to the deviation between the current and
required room temperature. This method of control is suitable for residential units
and houses with different temperature zones. The accuracy of control is greater and
the flow temperature is limited. This saves fuel.
The pump runtimes can be shortened by means of optimised running of the pump.
2.2
Function as remote control (Fb, for heat sources, heat pumps,
and ventilation units)
The CR 10 H can be used as a remote control for a higher-level user interface.
The time program is determined by the higher-level user interface. The required room
temperature or ventilation level can be temporarily changed at the CR 10 H until the
next switching time of the time program. After this, the higher-level user interface has
priority until the setting is changed again at the CR 10 H.
2.3
Functions as humidity-sensitive controller (OFF)
The CR 10 H regulates the ventilation system, according to the relative humidity in
the room, measured via the controller. It's possible to use up to four controllers. The
measurements are collected, assessed, and the ventilation level is adjusted
according to the highest value.
The ventilation control is also available in combination with a heating control (CO).