SO D15i
ROOM THERMOSTAT
By setting the room thermostat (1) at the desired temperature
level, the heater will start and stop automatically. When the
selected temperature level is reached, the fan only goes on for
some time.
SAFETY THERMOSTAT MANUAL RESET
A temperature-limit thermostat will stop power feeding in case of
overheating. If the thermostat releases, disconnect fan electricity,
wait until the fan has cooled and fix the problem causing
overheating.
To reset the temperature-limit thermostat, remove the cover and
press the switch (2).
MANTEINANCE
Warning
Before carrying out any maintenance operation you
must:
• Stop the heater;
• Turn off the disconnecting switch on the electric
switchboard;
• Wait until the heater has cooled down.
OBSERVED FAULTS, POSSIBLE CAUSES AND REMEDIES
OBSERVED FAULT
• The fan doesn't start
• The fan starts but there is not enough
heat
• The space heaters stops
Airchaud Diffusion - 35 route de Colmar, 67600 Sélestat
SIRET : 444 448 898 00015
EN
CLEANING
For the heater to operate efficiently, cleaning operations must be
carried out regularly. Dust and dirt may result in overheating and
fire.
DISPOSAL
At the end of its useful life, you have to scrap and dispose of this
product by taking it to a local differentiated waste collection center
in conformity to law.
Before scrapping, check the serial number plate on the machine:
if it has the symbol, it means that disposal is regulated by EU
Directive 2003/96 (Waste Electrical and Electronic Equipment,
WAEE).
The user must inquire about the local electrical and electronic
waste collection system and follow its instructions.
Illegal disposal of this product with normal domestic waste can
seriously harm the environment and health and is subject to
administrative penalties.
CAUSE
• No electrical current
• Winding of motor burnt or interrupted • Replace motor
• Wrong setting of room thermostat
• Defective room thermostat
• Safety thermostat intervenes
11
Tél. : 03 88 08 67 05
Fax : 03 88 08 67 39
REMEDY
• Check mains, it should be
• Check proper positioning and
functioning of switch
• Check correct setting of room
thermostat
• Replace room thermostat
• Identify the problem that caused the
overheating