3. Check that the suspension legs remain in the same plane. If you perceive a
different case, then loosen one of the screws. If the suspension legs have
moved in the same plane, then you should tighten the screw again.
4. Mount the hot water tank on the wall according to the above instructions.
In order to install the hot water tank, the following conditions should be
ensured:
-Adequate electricity, pipeline and waste water collection systems should be
ensured on the location of the installation.
-In order to reduce heat loss due to hot water pipe, it is highly recommended
that you install the unit close to locations using hot water. In case of larger
distance between the unit and the location using hot water, is it reasonable to
provide insulation for the hot water pipe.
5. PIPELINE CONNECTION
Any steel pipe, plastic pipe and red copper pipe or flexible pipe connection
adequate to a water pressure rated as 0.6 MPa can be used as hot or cold water
pipes.
In case of connecting red copper pipes to the pipeline system, the use of
insulating intermediate pieces is compulsory.
One of the intermediate pieces has to be mounted directly to the hot water
pipe of the water tank, while another intermediate piece has to be mounted
between the already fixed fittings and the red copper pipeline system. In case
of connection without intermediate pieces, our Company undertakes no
guarantee for defects due to corrosion of internally threaded pipe ends of the
water tank, neither any liability resulting from or related to such events. The
middle piece not accessory. Can be ordered: 3/4" Article Nr. 1252122513
The water tank should be connected to the pipeline system according to
Figure2.
IT IS AT THE RISK OF DEATH AND THEREFORE IT IS FORBIDDEN TO PUT THE
WATER TANK UNDER A PRESSURE LARGER THAN THE PERMITTED OPERATION
PRESSURE!
25