Overview Of Settings - BEA IXIO-DT1 INDUSTRIAL Mode D'emploi

Détecteur d'activation et de sécurité pour portes coulissantes automatiques
Masquer les pouces Voir aussi pour IXIO-DT1 INDUSTRIAL:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OVERVIEW OF SETTINGS

Back
More
RAD: FIELDSIZE
AIR: WIDTH
+
AIR: OUTPUT
TEST
More
Back
Back
More
RAD: FIELDSIZE
RAD: IMMUNITY
RAD: DIRECTION
RAD: HOLDTIME
RAD: REENTRY
RAD: OUTPUT
AIR: IMMUNITY
AIR: WIDTH
+
AIR: NUMBER
AIR: PRESENCE TIME
AIR: FREQ
AIR: OUTPUT
TEST
REDIRECTION
motion
FACTORY RESET
More
Back
ZIP CODE
all parameter settings in zipped format
(see application note on ZIP CODE – 76.0024)
ID #
unique ID-number
CONFIG P/N
SOFT P/N
ERROR LOG
last 10 errors + day indication
AIR: SPOTVIEW view of spot(s) that trigger detection
Page 6 of 9
0
0
1
1
2
2
3
3
small
>
>
>
DeEner/NO
Energ/NC
Energ/NC
Energ/NC
DeEner/NO
Energ/NC
off
on
Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control.
small
>
>
>
low
>
>
uni
off
bi
uni
MTF
0.5 s
1 s
2 s
3 s
small
>
>
>
DeEner/NO
Energ/NC
Energ/NC
Energ/NC
DeEner/NO
Energ/NC
normal
enhanced
1
2
30 s
1 min
A
B
DeEner/NO
Energ/NC
Energ/NC
Energ/NC
DeEner/NO
Energ/NC
off
on
Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control.
motion
or
presence
factory value
4
4
5
5
6
6
7
7
>
>
>
>
DeEner/NO
DeEner/NO
The sensor LED will briefly flash RED during monitoring communication with door control.
>
>
>
>
>
>
>
>
4 s
5 s
6 s
7 s
>
>
>
>
DeEner/NO
DeEner/NO
mode B
2 min
5 min
10 min
20 min
DeEner/NO
DeEner/NO
The sensor LED will briefly flash RED during monitoring communication with door control.
AIR: C1 ENERG
AIR: C2 ENERG
POWERSUPPLY
OPERATINGTIME
RESET LOG
PASSWORD
ADMIN
8
8
9
9
>
large
Always additionally adjust the
arrow position on the sensor with a
DeEner: De-Energized relay
This indicates that external monitoring is functional.
>
large
>
high
MTF: motion tracking feature
8 s
9 s
>
large
DeEner: De-Energized relay
Always additionally adjust the
arrow position on the sensor with a
min. value for DIN18650: 1 min
60 min
infinte
min. value for EN16005: 30 s
DeEner: De-Energized relay
This indicates that external monitoring is functional.
opening output is active in case of:
0 motion detection
1 motion or presence detection
2 motion and presence detection
full
partial
partial: outputs are not reset
reset
reset
signal amplitude received on curtain 1
signal amplitude received on curtain 2
supply voltage at power connector
power duration since first startup
delete all saved errors
LCD and remote control password
(0000= no password)
enter code to access admin mode
75.5784.11 IXIO-DT1 UL INDUSTRIAL 20180305
screwdriver.
Energ: Energized relay
NO: normally open
NC: normally closed
Energ: Energized relay
NO: normally open
NC: normally closed
screwdriver.
Energ: Energized relay
NO: normally open
NC: normally closed

Publicité

Table des Matières
loading