INFRARED SAFETY FIELD
OR
Activate the visible* spots to verify
the position of the AIR-curtain.
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than
8 in.
Always verify the actual detection field width by
walk-testing according to ANSI 156.10 guidance.
4
SET-UP
SET-UP 1 (QUICK)
reference picture
either hold the knob for 2 seconds, or use the
remote control buttons as specified
SET-UP 2 (ASSISTED)
test of full door cycle + reference picture
either hold the knob for 4 seconds, or use the
remote control buttons as specified
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
Page 5 of 9
CLOSER
AWAY
If necessary, adjust the AIR-curtain
angle (from -7° to 4°, default 0°).
Part of the detection field can be masked to reduce its width.
The arrow position determines the width of the detection field.
Additional
adjustments are
possible by LCD or
remote control
(see OVERVIEW OF
SETTINGS).
STEP OUT OF THE INFRARED FIELD!
+
Mounting
The size of the detection field varies according to the
mounting height and the settings of the sensor.
The full door width must be covered.
+
+
75.5784.11 IXIO-DT1 UL INDUSTRIAL 20180305
DOOR
max.
3 in**
Detection
height
width
6' 6"
6' 6"
7'
"
7'
"
3
3
16
16
8'
"
8'
"
3
3
16
16
9'
"
9'
"
13
13
16
16
11' 6"
11' 6"
2 s
OR
4 s
OR