Battery Replacement - TFA Kitchen Chef Mode D'emploi

Thermomètre de cuisson / du four numérique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
TFA_No. 14.1512_Anleitung
14.03.2018
Küchen-Chef – Digital BBQ meat / oven thermometer
• Confirm the setting with the ALARM button.
• "- -" appears on the oven temperature display and the symbol
• To activate the upper oven temperature alarm press the ON/OFF button. The alarm symbol
• 70°C (default) or the last adjusted value flashes on the display.
• You can use the + or – button to set the upper temperature limit.
• Confirm the setting with the ALARM button.
• "- -" appears on the oven temperature display and the symbol
• To activate the lower oven temperature alarm press the ON/OFF button. The alarm symbol
• 0°C (default) or the last adjusted value appear on the display. You can use the + or – button to set the lower temperature
limit.
• Confirm the setting with the ALARM button.
7.3 In case of alarm
• The device will alert you with a beep:
• As soon as the core temperature is reached
• If the set upper temperature limit in the cooking chamber is exceeded
• If the set lower temperature limit in the cooking chamber has fallen below
• The backlight turns on.
22
9:56 Uhr
Seite 12
and the alarm symbol
flash.
appears.
and the alarm symbol
flash.
appears.
Küchen-Chef – Digital BBQ meat / oven thermometer
• Press any button to stop the alarm sound.
• The alarm symbol
will continue flashing until the measured core temperature has fallen below the set temperature
limit or until the measured oven temperature is within the alarm limits.
• The alarm sound automatically turns off after 3 minutes if not stopped manually.
• To turn off the alarm functions, press the ON/OFF button in the respective alarm mode. The alarm symbol
8. Care and maintenance
• Clean the instrument and the probe with a soft damp cloth. Do not use solvents or scouring agents. Protect it from mois-
ture.
• Should water or steam enter the device's jack, it could affect the contact with the probe. Dry the probe connector with a
cloth before connecting it to your instrument.
• Turn off the instrument after use.
• Remove the batteries if the device will not be used for an extended period of time.
• Keep the device in a dry place.

8.1 Battery replacement

• Change the batteries when the battery symbol appears on the display.
• Open the battery compartment and insert two new AAA 1.5 V batteries, polarity as illustrated.
• Close the battery compartment again.
appears.