OVERHEAD RIGGING

• Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
• Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
• Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
• The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
• Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
• Fix two screws on the mounting surface at an appropriate distance. (the distance between the two fixing
holes of the blacklight strip is to be measured by the user)
• These screws should have a diameter of about 3 to 4mm with a head diameter of 8 to 9mm.
• Fasten both screws until there's a gap of about 2mm between the head of the screws and the mounting
surface.
• Gently slide the fixing holes of the blacklight strip over the two screws.
• The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
• Don't cover any ventilation openings as this may result in overheating.
• The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
OPERATING INSTRUCTIONS
• Once connected to the mains you can switch the device on/off with the mains switch.
• The UV lamp needs 3-4 minutes warm-up time until it reaches full lighting output.
• Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.
• Do not switch the unit on and off in short time intervals as this reduces the lamp life.
• The lamps' surface temperature may reach up to 80°C. Don't touch the lamp with bare-hands during its
operation.
• Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
• In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
• Important: Never look directly into the light source! Don't use the effect in the presence of persons
suffering from epilepsy.
JB SYSTEMS®
OPERATION MANUAL
3/20
BLACKLIGHT STRIP
ENGLISH
MAINTENANCE
• Make sure the area below the installation place is free from unwanted persons during servicing.
• Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
• All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
• Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
• When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
• The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
• In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
• The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
• The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
• Clean with a soft cloth using normal glass cleaning products.
• Always dry the parts carefully.
• Clean the external optics at least once every 30 days.
• Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Small model – 18W (code: 3803)
Mains Input:
AC 230V, 50Hz
Lamp:
T8-18W 60cm UV-lamp with G13 fittings
Size:
62 x 10 x 4cm
Weight:
1.8kg
Large model – 36W (code: 3802)
Mains Input:
AC 230V, 50Hz
Lamp:
T8-36W 120cm UV-lamp with G13 fittings
Size:
124 x 10 x 4cm
Weight:
3.2kg