36" GAS COOKTOPS
ZGU385NSMSS, Natural Gas Model
ZGU385LSMSS, LP Gas Model
IMPORTANT NOTICE: This information is intended
for use by persons possessing adequate
backgrounds of electrical, electronic and
mechanical experience. Any attempt to repair a
major appliance may result in personal injury
and property damage. The manufacturer or seller
cannot be responsible for the interpretation of
this information, nor can it assume any liability
in connection with its use.
DISCONNECT POWER BEFORE SERVICING
IMPORTANT: Reconnect all grounding devices.
All parts of this appliance capable of conducting
electrical current are grounded. If grounding
wires, screws, straps, clips, nuts or washers used
to complete a path to ground are removed for
service, they must be returned to their original
positions and properly fastened.
GAS REQUIREMENTS
GAS SUPPLY REQUIREMENTS
INCOMING
GAS TYPE
PRESSURE TO
PRESSURE REGULATOR
REGULATOR
OUTPUT SUPPLIES
Natural
6.0" to 14.0" W.C.P.
5.0" W.C.P.
L.P.
11" to 14" W.C.P.
10.0" W.C.P.
CAUTION
— The cooktop, as shipped
from the factory, is set for use with its intended
gas. If you wish to use your cooktop with the
alternate gas, you must first replace the
orifices and convert the pressure regulator.
WARNING
— This conversion must
be performed by a qualified installer or gas
supplier in accordance with the manufacturer's
instructions and all codes and requirements of
the authority having jurisdiction. Failure to
follow instructions could result in serious injury
or property damage. The qualified agency
performing this work assumes responsibility
for the conversion.
CAUTION
— The following adjustments
must be made before turning on the burner.
Failure to do so could result in serious injury.
Be sure pressure regulator has been converted
as described in Step 1.
ZGU385 GAS CONVERSION
INSTALLATION INSTRUCTIONS
1
ADJUST THE REGULATOR
A. Disconnect all electrical power, at the main circuit
breaker or fuse box.
B. Shut off the gas supply to the cooktop by closing
the manual shut-off valve.
C. Adjust the pressure regulator by the following
instructions:
• Unscrew the cap.
• Place your thumb against the flat side of the spring
retainer and press down to remove the retainer.
• Carefully look at the spring retainer to locate the NAT
or LP position.
Gasket
Cap
NAT
LP
Spring
retainer
NAT
LP
L.P./propane
NAT.
position
position
Pressure regulator
• Turn the spring retainer over so that the desired
gas is showing on the bottom.
• Snap the retainer back into position.
• Screw the cap back onto the regulator.
2
CHANGE BURNER ORIFICES
INSTALLATION TIP: First remove all orifices and then
start replacing them. This will help to prevent the
possibility that some may not be replaced.
A. Remove the burner grates, burner caps and burner
heads.
B. Using a 7mm nut driver, remove the top burner
orifices. There are two orifices per burner.
The main orifice is located low in the center of the
burner, while the simmer orifice is located higher
beside the center of the burner.
IMPORTANT: Orifices must be located exactly as shown.
Carefully read and observe each orifice label for correct
location.
C. Install the proper orifices in the exact locations as
noted in the illustrations at right.
D. Return the gas orifices to the bracket and reattach
the bracket and the instruction sheet to the pressure
regulator using the screw removed previously.
E. Replace the burner heads, caps and top grates.
3
ADJUST BURNER FLAMES
A. Turn all burners on highest setting and check the
flames. They should be blue in color and may have
some yellow tipping at the ends of the flame when
using LP gas. They should be blue (no yellow tipping)
when using natural gas. Foreign particles in the gas
line may cause an orange flame at first, but this will
soon disappear.
B. Turn the cooktop burner knob to "LO" while
observing the flame.
Adjust the setting of the upper row of flames using
the valve bypass screw as follows:
Adjustments must be made with two other burners in
operation on a medium setting. This prevents the upper
row of flames from being set too low, resulting in the
flame being extinguished when other burners are
turned on.
C. To adjust the flame, remove the knobs. Insert a small
flat blade screwdriver (3/32" [2–2.4mm] tip) through
the access hole in valve shaft as shown at right.
• If the flames were too small or fluttered, open the
valve more than the original setting.
• If the flames blew away from the burner, close the
valve more than the original setting.
D. Make the adjustment by slowly turning the screw
until flame appearance is correct.
E. Testing Flame Stability:
Test 1 – Turn the knob from "HI" to "LO" quickly.
If the upper row of flames goes out at this
setting, increase the flame size and test again.
Test 2 – With the burner on "LO", open and close the
cabinet door under the cooktop. If the flame
is extinguished by the air currents created
by the door movement, increase the flame
height and test again.
NOTE: When the burner is on the "SIM" setting, the
upper row of flames will go out, while the lower flame
remains on.
F. Flame Recheck:
After the adjustment is made, turn all burners off.
Ignite each burner individually. Observe the flame at
the "HI" position. Rotate the knob to the lowest setting
and be sure that the flame size decreases as the knob
is rotated counterclockwise.
Once the conversion is complete and checked ok,
fill out the conversion sticker and include your
name, organization and date conversion was made.
Apply the sticker near the cooktop gas inlet opening
to alert others in the future that this appliance has
been converted. If converting back to the original
gas, please remove the sticker so others know the
appliance is set to use its original gas.
Burner cap
Burner
head
Burner
Spark igniter
base
Simmer
Main
orifice
orifice
SIMMER
ORIFICES
MAIN
84XL
138XN
ORIFICES
108XL
190XN
84XL
148XN

Publicité

loading

Sommaire des Matières pour Monogram ZGU385 Serie

  • Page 1 Burner cap ZGU385 GAS CONVERSION INSTALLATION INSTRUCTIONS 36″ GAS COOKTOPS ZGU385NSMSS, Natural Gas Model Burner ZGU385LSMSS, LP Gas Model head ADJUST THE REGULATOR ADJUST BURNER FLAMES IMPORTANT NOTICE: This information is intended A. Disconnect all electrical power, at the main circuit A.
  • Page 3 INSTRUCTIONS D’INSTALLATION POUR Couvercle du brûleur N° de pièce 229C5530P001-0 LA CONVERSION DU GAZ—MODÈLE ZGU385 SURFACES DE CUISSON AU GAZ DE 91,5 CM (36 PO) ZGU385NSMSS, Modèle au gaz naturel Tête ZGU385LSMSS, Modèle au gaz de pétrole liquéfiés AJUSTEZ LE RÉGULATEUR DE PRESSION AJUSTEZ LA FLAMME DU BRÛLEUR AVIS IMPORTANT : Cette information est destinée aux A.

Ce manuel est également adapté pour:

Zgu385nsmssZgu385lsmss