6
Technical data
Category
Indirect ¿ ring, low speed
Length
Weight
max. 500 shooting nails per
Setting Frequency
3 charge/¿ ring strengths,
Power Regulation
6-stage power regulation
using a power regulator
L
Sound Pressure
Level
L
pA
+/- 2 dB (A)*
Vibrations
*Noise measurement according to EN 15895
and using EN ISO 3744, EN ISO 4871 as well as
EN ISO 11201.
Measurement conditions: Strongest charge
(red) intended to be used with adjusted shooting
nail. Triggered on a concrete block, device
facing vertically downward. The measured noise
emission values and associated measurement
uncertainties constitute the upper limit of the
values to be expected.
The work environment, workpiece support,
workpiece, contact pressing force and so forth
affect the noise development at the place of
operation and the effects of vibrations on the
object.
Type
63 mm (without pre-drilling)
Length, max.
76 mm (with pre-drilling)
Calibre*
Type
green (3) weak charge
Charge/¿ ring
yellow (4) medium charge
strengths*
red (6) very strong charge
* DIN EN 16264: 2013
All manuals and user guides at all-guides.com
Type PA3500
340 mm
2.35 kg
hour
(Measurement area)
pA
99 dB(A)
(Workplace) 104 dB (A)
L
138 dB (A)
pC
L
112 dB (A)
WA
< 2.5 m/s²
Shooting nails
Head nails Ø 7.6 mm
Cartridge strips
.27 cal. (6.8/11)
Cartridge strips
(10 cartridges)
7
Troubleshooting
Only perform troubleshooting measure that are
speci¿ ed here.
The Powder Actuated Tool may only be
maintained and repaired by an authorized
specialist workshop.
Cartridge strip does not ¿ re:
Cause(s)
Barrel not pressed
¿ rmly enough against
the surface
Malfunction of the
cartridge strip
Powder Actuated Tool
defective
Barrel or piston blocked:
Cause(s)
Powder Actuated Tool
has overheated
Foreign object in the
barrel or piston guide
Bent barrel
Non-approved shooting
nails
Powder Actuated Tool
defective
Performance weak or À uctuating:
Cause(s)
Interior parts of the
device dirty or worn
English
Measure(s)
Press the barrel harder
against the surface
Insert new cartridge
strip
Have the Powder
Actuated Tool be
repaired by an
authorized specialist
workshop
Measure(s)
Let the Powder
Actuated Tool cool
down
See chapter 5
"Inspection and
cleaning"
Have the Powder
Actuated Tool be
repaired by an
authorized specialist
workshop
See chapter 2.3
"Shooting nails" and
chapter 6 "Technical
data"
Have the Powder
Actuated Tool be
repaired by an
authorized specialist
workshop
Measure(s)
See chapter 5
"Inspection and
cleaning"
41