If the flue tube goes through a ceiling and/or roof
that consist of flammable materials, the ceiling and
the roof must be covered with fireproof materials all
around (about 80 cm). Pay also attention to joisted
floor layers and any electric wiring.
5.
Keep a distance of at least 50 cm (in all directions)
between the stove and supporting steel construc-
tion parts.
6.
Shield off all combustible materials within a radius
of 80 cm from the stove openings with non-com-
bustible materials.
7.
The wall behind the stove must consist of, or be
insulated with, fire-proof materials. The insulation
material must resist a temperature of 700 °C and
have a density of 80 kg/m3. Please see for insulation
materials table on page 22).
8.
Avoid heat transmission when placing the stove.
Heat transmission of a burning stove can penetrate
the wall and even cause fire damage on the other
side of the wall. Prevention is better than cure.
Installation
The Solea is tested in accordance with the international
EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to flue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a flue
tube to which several stoves are connected. The Solea
should never been integrated into the construction of the
room.
The heating device must be placed and connected by an
acknowledged installer and according to the installation
instructions given below. The national and local rules
and regulations for placing and using wood-burning
stoves are equally applicable. WANDERS does not give
any guarantee if the Solea is connected or installed
incompletely or incorrectly.
Supply of combustion air
The stove must have a sufficient fresh supply of
combustion air. To avoid draft, make if necessary an
extra air supply opening as close to the stove as possible.
An extra air supply opening is definitely required if:
The air supply opening must be sealable if it goes through
a fire-resistant wall. If there are several heating devices
in the same room there must be enough air openings to
guarantee proper combustion.
20
Connecting the fireplace
Be sure that the floor is strong enough to hold the weight
of the hearth without problem.
Before mounting the hearth, follow the instructions
given in the previous chapter. Protect the floor when you
mount the stove, and mind your back.
1.
Connect the Solea Elegance to an existing chim-
ney.
2.
The under-pressure in the flue tube must be 10 to 12
Pa (0.1 to 0.12 millibars).
3.
Take precautionary measures against fire (see points
1 to 8 on page 19)
4.
Place the stove at the selected place.
5.
Level the stove.
6.
Place the pipe between the stove and the outlet
channel. Connect a Ø 150 mm tube to the coupling
unit (the mouthpiece) in the straightest possible line
from the stove to the chimney. The tube must be
made of steel with a thickness of at least 2 mm.
Please keep in mind that the tube will expand in the
length by about 1 cm per meter, and verify that the
outlet is not jammed between the mouthpiece and
the ceiling.
Repairs
Replacing the glass
Remove the 4 screws and the spring plates in the inside
corners of the door. Carefully remove the glass and any
fragments. Remember the glass is very sharp.
Replacing the glass of Solea Elegance