TROUBLESHOOTING CHART

SYMPTOMS
1. Float valve
A. Refill tube pushed too far down on overflow
pipe.
turns on/off
by itself
B. Flush valve flapper ball worn, dirty, or
without
misaligned with flush valve seat; or seat
toilet being
corroded so flapper will not seal.
flushed.
C. Seat corroded so flapper will not seal.
D. No slack in chain assembly; housing assembly
is misaligned.
E. No slack in flapper chain assembly; flapper is
held off seat.
2. Float valve
A. Foreign particles lodged to valve seat or valve
seat washer.
continues
to run,
B. Float valve seal (located under valve cap)
allowing
cracked or split.
water to
C. Sensor wire interferes with float valve
enter tank.
operation.
3. Incorrect
A. Float valve not adjusted to correct water level.
water level
height.
4. Long or
A. Plugged valve inlet or supply line.
noisy tank
fill cycle.
5. Poor flush.
A. Water level is too low.
B. Trapway or rim holes are obstructed.
C. Soil pipe or vent is obstructed.
D. Supply shut-off valve not fully open.
6. Toilet seat
A. Batteries are dead.
movement
will not
B. Seat not in up raised position for 20 seconds
flush toilet.
or more.
C. Activation sensor not attached to front center
of tank.
D. Seat does not have oval-shaped magnet on
front center of underside.
E. Defective housing assembly.
A
1007285-2-
PROBABLE CAUSES
CORRECTIVE ACTION
A. Attach refill tube to overflow pipe above the
water line.
B. Inspect, clean and, if necessary, replace flapper
ball and/or seat.
C. Replace seat.
D. Move housing assembly to proper position.
E. Adjust flapper chain assembly for proper slack.
A. Clean valve seat//seat washer, or replace
piston/seat washer assembly.
B. Replace valve assembly.
C. Reposition sensor wire.
A. Adjust water tank level.
A. Clean valve seat/seat washer, or replace
piston/seat washer assembly.
A. Adjust tank water level.
B. Unclog trapway; clean rim holes.
C. Clear obstruction from soil pipe or vent.
D. Open supply shut-off valve.
A. Replace batteries with two D-size 1.5 volt
Alkaline batteries.
B. Completely raise seat against tank surface for at
least 20 seconds, then lower to toilet rim.
C. Reattach or relocate activation sensor.
D. Replace with required Peacekeeper seat.
E. Replace housing assembly.
7